 6 - White Rodgers 36E Gas Valve - Switch gas valve lever
to OFF. See figure 2.
Honeywell VR8205 Gas Valve - Turn knob on gas valve
clockwise
 to  OFF. Do not force. See figure 3.
WHITE RODGERS 36E SERIES GAS VALVE
GAS VALVE SHOWN IN OFF POSITION
FIGURE 2
ON
OFF
HONEYWELL VR8205 SERIES GAS VALVE
GAS VALVE SHOWN IN OFF POSITION
FIGURE 3
 7 - Wait five (5) minutes to clear out any gas. If you then
smell  gas,  STOP!  Immediately  call  your  gas  supplier
from  a  neighbor's  phone.  Follow  the  gas  supplier's
instructions. If you do not smell gas go to next step.
 8 - White Rodgers 36E Gas Valve - Switch gas valve lever
to ON.
Honeywell  VR8205  Gas  Valve  -  Turn  knob  on  gas
valve counterclockwise
  to ON.  Do not force.
 9 - Replace the access panel.
10 - Turn on all electrical power to unit.
11 - Set thermostat to desired setting.
NOTE – When unit is initially started, steps 1 through 11
may need to be repeated to purge air from gas line.
12 - If  the  appliance  still  will  not  operate,  follow  the
instructions To Turn Off Gas To Unit" and call your
service technician or gas supplier.
To Turn Off Gas To Unit
 1 - Set thermostat to lowest setting.
 2 - Turn off all electrical power to unit if service is to be
performed.
 3 - Remove the access panel.
 4 - Switch lever on White Rodgers gas valve to OFF; turn
knob on Honeywell valve clockwise
 to  OFF. Do not
force.
 5 - Replace the access panel.
Filters
G24M series units are equipped with external filters
which  should  be  inspected  monthly  and  replaced
when necessary to assure proper furnace operation.
See table 1 for filter sizes. Replacement filters used
with G24M-40/60/75 units must have a minimum veĆ
locity  rating  of  400  FPM.  Replacement  filters  used
with G24M-100/120/140 units require a minimum veĆ
locity rating of 625 FPM. Figures 4, 5, and 6 show posĆ
sible filter locations.
TABLE 1
FILTER SIZE
MODEL NUMBER
UPFLOW
DOWNFLOW
1 FILTER
2 FILTERS
G24M-45/60/75
16 in. X 20 in. X 1 in. 16 in. X 20 in. X 1 in.
G24M-100/120/140
20 in. X 20 in. X 1 in. 16 in. X 20 in. X 1 in.
UPFLOW FURNACE
BOTTOM RETURN AIR
FIGURE 4