Windsor PT-20 User Manual

Page of 18
PROBLEM 
No 
power. 
Vacuum motor 
does not run. 
Brush motor 
does 
not 
run. 
Solution light 
does not work. 
Battery charge 
level Indicator 
lights. 
PROBABLE CAUSE 
Circuit breaker tripped. 
Battery cables corroded 
at battery terminals. 
Faulty main switch. 
Faulty safety  override 
micro switch. 
Faulty solenoid. 
Circuit breaker tripped. 
Loose connections. 
Faulty 
circuit 
breaker. 
Faulty 
switch. 
Motor brushes worn. 
Circuit breaker tripped. 
Loose connection. 
Faulty solenoid. 
Faulty drive motor. 
Faulty circuit  breaker. 
Loose connections. 
Faulty solution light. 
Light stay on with 
solution lever in 
“OFF”  position. 
No light are on with 
main switch on. 
Loose connections. 
CORRECTIVE ACTION 
Reset brush motor circuit breaker 
(50 amp). 
1. Clean battery cable clamps and battery terminals. 
2.  Check voltage at points A and 
Voltage should be 22/26 VDC. 
1. 
Check voltage at points A and C.  Voltage should be 22/26 VDC. 
2.  Turn  main  switch  on  and check  voltage  at  points A  and  D.  Voltage  should  be 
With main switch 
“ON”  check voltage at points A and 
and A and F. Voltage should 
be 22/26  VDC. 
If  no voltage  at  A and  F  remove leads and check  micro switch for 
continuity.  Should be continuity 
in 
normal position and no continuity  when switch 
lever is activated. 
With main switch on (solenoid energized) check voltage at points 
and 
voltage 
should be 22/26 VDC. 
I f  no voltage replace solenoid. 
Reset 
motor circuit  breaker. 
Check  motor  lead  connections  at  terminal  block  and 
connector  near 
motor.  Keep all connections  tight. 
With  main switch  on  check  voltage  at  points A  and  H and A  and  I.  If  no voltage, 
check continuity of  circuit breaker. Replace as needed. 
Remove leads and check switch for continuity. Replace as needed. 
Check  motor  brushes.  Replace when  worn  to 
Check 
motor  by  securing 
motor and applying 24 VDC to motor leads. 
No load amp draw  of  motor should be 
15 
amp. 
Reset 
(50 amp) brush motor circuit breaker. 
Check motor leads at terminal block connection (located under right hand lower 
side panel) tighten set screws as needed. 
With main switch on check ouput voltage at points A and 
G. 
Voltage should be 
22/26 VDC. 
Check  motor  brushes 
replace when  worn  to 
With  batteries  fully  charged 
and motor secured, apply battery voltage direct to motor. 
No load amp draw 
of 
motor 
should be 12 to 13 amps. 
Reset (6 amp) battery circuit breaker. 
Check for loose electrical connections at terminal block, solution switch,  and 
solution light. 
Remove light and apply direct  battery voltage (24  VDC) to light.  Replace light as needed. 
Adjust solution light switch. 
22/26 VDC. 
If no voltage remove leads and check switch for continuity, 
Check (6 amp) battery circuit breaker. Reset 
i f  tripped. 
1. 
Check electrical connections  at circuit breaker. 
2.  Check voltage at inline connector at PC Board. Should be 22/26 VDC. 