TROUBLESHOOTING CHART
 
CADET  86038340  04/19/07 
  4-4ENG 
PROBLEM CAUSE 
SOLUTION 
No Power, Nothing Runs 
1. Is the cord plugged in. 
2. Circuit breaker tripped in building. 
3. Faulty switch. 
4. Faulty power cord or pigtail. 
1. Plug in cord. 
2. Reset breaker 
3. Call for service. 
4. Call for service. 
Vacuum Motor Will Not 
Run 
1. Vacuum circuit breaker tripped. 
2. Faulty main vacuum switch. 
3. Loose wiring. 
4. Faulty vac motor.    
1. Reset breaker 
2. Call for service. 
3. Call for service. 
4. Call for service. 
Vacuum Motor Runs But 
Suction Is Poor 
1. Debris lodged in vac shoe. 
2. Dome gasket defective or missing. 
3. Vacuum hose cracked or hose cuff loose. 
4. Recovery tank full / float ball stuck in the up 
    position. 
1. Remove debris from vac shoe. 
2. Replace as necessary. 
3. Replace or repair as necessary.  
4. Turn off vac motor. Drain and rinse 
     recovery tank. 
Poor Or No Water Flow 
(Carpet Is Streaky) 
1. Main pump switch off. 
2. Jets clogged or missing. 
 
3. Solution filter clogged. 
 
4. Faulty solenoid. 
1. Turn on. 
2. Clean using a vinegar /water solution or 
    replace. 
3. Drain solution tank and clean solution 
    filter. 
4. Call for service. 
Brush Does Not Spin 
1. Brush switch off. 
2. Brush circuit breaker tripped 
3. Brush belt broken. 
4. Faulty brush motor. 
1. Turn on brush switch. 
2. Reset circuit breaker. 
3. Replace as necessary. 
4. Call for service.