Windsor D250 User Manual

Page of 19
                                 OPERATIONS
D-250  98637 0 1/15/99
4
CARPET INSPECTION:
Determine precisely what areas you are
going to clean.  Note problem areas in the
carpet or tack strip.  Look for loose carpet,
heavily damaged areas, discolored stains,
or grease spots that will require prespotting.
Note the carpet type.  Check the availability
of hot water, drains, and suitable electrical
outlets.  If the carpet is loose or worn, have
it repaired before attempting to clean it.
Plan the cleaning route, work from the most
remote area towards the exit.  Try not to
travel over the cleaned areas when getting
fresh water or dumping old.  Furniture
should be moved out away from the walls
before cleaning.  If furniture is moved back
in place before carpet is completely dry,
place plastic or foil protectors under the
legs to prevent possible carpet staining.
When possible use a Windblower (WB3)
and open all windows and doors to speed
carpet drying.
ACCESSORIES:
The D-250 can be used with the following
Windsor equipment: Deluxe Hand Tool
(DHT), Pile Jogger(PJ2A),  Standard Floor
Wands(SFW, SW, SW-PRO, PROW), &
Wind Blower carpet dryer(WB3).  Contact
an authorized Windsor dealer for
assistance in choosing the right equipment .
GENERAL  INFORMATION:
On heavily soiled carpets, or on areas of
high foot traffic
, it may be necessary to
use a prespray or traffic lane cleaner
applied with a Pro-Spray.  Do not add
presprays to the machine's solution tank.  If
a spotter is used, follow the manufacturer's
instructions exactly as printed on the label.
Remove the spotter with the floor tool when
done, spotter left in the carpet may bleach
or brown it permanently.
As the carpet is being cleaned, check to
see if there is  foam building up in the
recovery bucket.
  Add a little defoaming
compound to the recovery tank but never to
the solution tank.
For infrequent use or long periods of
storage
, flush the system with a
neutralizing solution of 1 quart white
vinegar mixed with 2 gallons hot water.
Flush the system with clean hot water after
neutralizing.
For hose fitting lubrication, use a light
silicone lubricant which will not damage o-
rings.
PROTECT THIS MACHINE FROM
FREEZING.