MAINTENANCE 
86037780  EXTRACTOR  05/09/08 
                       
4-1 
 
PROTECT FROM FREEZING 
 
If it becomes necessary to store in temperatures that 
could drop below 40°F, the pumping system, hoses  
and valves must be protected from freezing with a 
methyl hydrate window washer antifreeze solution. 
 
NOTE: Do not use ethylene glycol or cooling system 
antifreezes. 
 
1.  Add one gallon of window washer antifreeze to 
     the supply tank. 
 
2.  Turn on pump switch and spray until the 
 
anti-freeze solution fills the solution lines. 
 
3.  Drain the leftover antifreeze from the supply tank.  
Always allow the unit to reach room temperature 
before filling with hot water or operating. 
 
4.  Before operation be sure to flush system 
 
completely.  Failure to do so after winterizing 
 
machine will damage carpet. 
 
DAILY/REGULAR MAINTENANCE 
 
Before making any 
adjustments or repairs to 
the machine, disconnect the power cord from the 
electrical source.  
 
1.  Empty unused cleaning solution from the 
 solution 
tank. 
 
2.  Inspect and clean filter at solution tank fill port 
and at the vacuum intake port in the dome. 
 
3.  Flush pumping system with 1 to 2 gallons of 
 
clean, hot water. 
 
4.  Check spray jet for full spray pattern. 
 
5.  Empty the recovery tank and rinse with clean 
water. 
 
6.  Check for and remove any lint or debris around 
brush and vac shoe. 
 
7.  Clean float screen and check float valve to make 
sure it moves freely. 
 
PERIODIC MAINTENANCE 
 
1.  After every 25 hours of operation, flush a white 
 
vinegar solution (ONE quart vinegar to two 
 
gallons of water) or anti-browning solution (mixed 
 
as directed) through the extractor.  This will 
 
prevent build-up of alkaline residue in the system. 
 
2.  If the spray jet becomes clogged, check for debris 
and clean surface of jet. 
 
NOTE: Do not use pins, wire, etc. to clean spray jet 
nozzle as this will deform the jet and destroy the 
spray pattern. 
 
3.  Periodically inspect all hoses, electrical cables,  
filters, gaskets and connections on your machine.  
Frayed or cracked hoses should be repaired or 
replaced to eliminate vacuum or solution 
pressure loss. 
 
4.  The electrical cable must be well insulated, if the  
 
cable insulation is broken or frayed, repair or 
 
replace it immediately.  Don't take chances with  
 
electrical fire or shock. 
 
5.  The filter in the bottom of the solution tank and at 
the fill port must be clean to allow free flow of 
cleaning solution. The screen filter on the vacuum 
intake in the dome must be free of lint buildup to 
ensure full vacuum strength. 
 
6.  The dome gasket must be properly seated and 
 
free of damage to create the air seal needed to  
     extract water.