Sterling 90-225 CFM User Manual

Page of 52
 
 
Cabinet Series Dehumidifying Dryer 
 
22 
 
PLC LED Indicators 
The following indicators are located inside the dryer cabinet.  See Figures 5, 6, and 7. 
Name 
Description 
System 
Start/Sequence 
Shutdown (I/0) 
When ON, activates the operation of the dryer 
portion. 
Compressed Air 
Input (I/1) 
When ON, confirms that compressed air is present. 
Process Blower 
Enable (I/2) 
 
When ON, Confirms the operation of the process 
blower. 
Bed Switch Set 
Point Input (I/4) 
 
When ON, indicates that dewpoint is above bed 
switching set point. 
High Regen 
Temp Alarm, 
Right Bed (I/5) 
 
When OFF, indicates a situation of a temperature 
exceeding the set level in the right regen bed. 
 
High Regen 
Temp Alarm, 
Left Bed (I/6) 
 
When OFF, indicates a situation of a temperature 
exceeding the set level in the right regen bed. 
Compressed Air 
Alarm Input (I/7) 
 
When ON, it indicates loss of compressed air. 
High Process 
Temp Alarm (I/8) 
 
When ON, sends the information to the PLC to be 
used later in forming alarm procedure. 
Push To Silence 
(I/9) (Optional) 
 
When the existing rocker switch is pressed, the 
audible horn will be silenced and flashing strobe 
will be turned off. Also, it serves as an alarm 
acknowledgment.