Sterling 350-2100 CFM User Manual

Page of 58
350-2100 cfm Dryers 
Chapter 4: Control Panel 
23 of 58 
 
;  If one or two of a heater's three meters indicates a low reading, a burned-out heater is 
likely, and should be serviced.  
 
4-3 PLC 
Control 
These dryers are equipped with an Omron C28K programmable logic controller (PLC). 
The "brick" type PLC has 28 I/O points - 16 inputs and 12 outputs.   
All inputs are 115 VAC, except for the 24 VDC input #1 from the dewpoint circuit board. 
All programming and logic is factory installed on an EPROM, and cannot be modified. 
A battery backup retains the programming during power failures. 
Battery life is 5 years at room temperature. 
If the alarm indicator blinks intermittently, replace the battery [P/N A0544701] within one 
week. 
4-4  Process Air Temperature Controller 
Standard ACS dryers use a microprocessor based PID control for maintaining process air 
temperature. The controller is a modular, self-contained unit that can slide from its mounting 
housing. All parameters except for the process air setpoint are factory set and adjusted; no 
field adjustment to the internal controls is normally necessary.