Ultra-Aire 90H Installer’s & Owner’s Manual
FOR HVAC INSTALLER AND HOMEOWNER
2.    Press the program enter key to toggle to the “open for” 
setting.  Using the up/down 
“RH”  keys, change the 
duration that the damper will ventilate fresh air.
3.    Press the program enter key to toggle to the “closed 
for” setting.  Using the up/down 
“RH”  keys, change the 
duration that the damper will remain closed between 
ventilation.
For the example given, starting at 8:00AM in the morning, 
the control will ventilate fresh air for 15 minutes then stop for 
15 minutes.  This schedule of 15 minutes open; 15 minutes 
closed will continue until the start time of the night schedule.
Press 
“PROGRAM ENTER”  again to go to the “MON-FRI” 
night schedule.  Repeat the steps listed above for this and the  
“SAT-SUN”  day and night schedules.
When you return to the main program menu, use the 
up/down 
“RH”  buttons to select “RUN PROGRAM.”
Press 
“PROGRAM ENTER” to run the program. The 
display will appear as follows:
5.3I Temperature Cutout Programming
Ultra-Aire units produce heat when dehumidifying. Depending 
on outside conditions, the ventilation function may introduce 
warm air into the space. Occasionally, the operation of the 
Ultra-Aire may produce enough heat to drive temperatures up. 
The temperature cutout feature disables all Ultra-Aire operations 
if temperatures reach cutout setpoint. In most installations this 
feature will not need to be used. If temperature cutout is desired, 
program the setpoint by pressing the 
“PROGRAM ENTER” 
button. Press RH until 
“TEMP CUTOUT”  is flashing. Use “RH”  
up or 
“RH”  down to adjust setpoints.
5.3J Default Settings
Upon initial power-up or after prolonged power outages (more 
than 30 minutes), the DEH 3000 is programmed with the 
following defaults. A space is provided to make note of user 
inputs.
Setting 
Default 
My Setting
RH setpoint 
50% 
__________
Ventilation Operation 
Closed 
__________
Fan Setting 
Auto 
__________
Temp Cutout 
80% 
__________
If you have questions about the  
DEH 3000, please call Therma-Stor LLC  
at 1-800-533-7533 or email us at  
sales@thermastor.com
Vent schedule 
on time/off time
Program 
RUN mode