FIELD CONTROLS UV-1500C User Manual

Page of 8
 
Page 2
I. 
INDICATION FOR USE 
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 
use in the mitigation, treatment, or prevention of any disease or condition. 
II. GENERAL 
INFORMATION 
Model 
Volts 
Amps 
Hz 
Watts 
Lamp Intensity 
at 1 meter 
Recommended 
Max Sq. Feet 
Weight 
Width 
(Inches) 
Height 
(Inches) 
Depth 
(Inches) 
UV-1500C 120 1.3 60 130  37 
μW/cm
2
 
1500 15.5 
Lbs 
18 
23-3/4 
6-5/16 
 
WARNING: This product is designed for indoor installation only. 
The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room sitting on 
the floor, it can be mounted on the wall to maximize floor space or it can be mounted into a suspension (drop) ceiling.  
 
F
EATURES
 
1.  The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit from 35 
cfm to 100 cfm. 
2.  The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front access 
door is opened. 
3.  The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the 
operation of the lamp through a LED indicator light mounted on the front access door.  The circuit board 
indicates good operation of the lamp by a continuous “GREEN” color on the LED light.  After 8320 hrs of lamp 
operation, the circuit board indicates the elapsed time of lamp operation by a continuous “YELLOW” color on 
the LED light and the internal alarm will beep every 15 minutes.  After 9000 hrs of lamp operation, the circuit 
board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED light and the 
internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out.  The circuit 
board will indicate this by a continuous “RED” color on the LED and the internal alarm will beep every 5 
minutes. 
III. UV-1500C 
CHECK OUT PROCEDURE  
1. 
Plug the power cord into a standard 120-volt wall receptacle. 
2. 
Turn the speed control knob clockwise to turn the unit on.  After the fan has started, the LED light will show a 
continuous “GREEN” color indicating proper unit operation. 
3. 
Once you have determined that the unit is functioning properly, turn unit off and unplug. 
4. 
Continue to next section for mounting options. 
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness.  Never operate the UV-Aire™ Air Purifying System with the UV chamber door open. Avoid touching the glass portion of the
lamp with your hands.