2.  Determine the type of duct you have. 
(For flex duct applications, refer to Figure 21 on page 8) 
I
F YOU HAVE METAL DUCT
a.  Apply supplied wet and stick mounting template to air duct 
in either a vertical or horizontal position as shown in Figure 
2. 
b.  Drill 1/8” diameter mounting holes at positions indicated on 
template. 
c.  Cut out rectangular hole on template using a pair of tin 
snips or jigsaw. (See Figure 2) Remove template. 
I
F YOU HAVE DUCT BOARD
a.  Mount the supplied metal mounting plate onto the duct with 
duct tape in either a vertical or horizontal position as shown 
in Figure 2. (See Figure 3) 
b.  Bend tabs outward as shown in figure 4. 
c.  Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See 
Figure 5) 
d.  Remove the cut piece of duct. (See Figure 7) 
e.  Bend both tabs down and through duct at first bend point. (See Figures 8 &9) 
f.  Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. 
(See Figures 10 & 11 
g.  Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See 
Figure 12) 
Figure 2
 
Figure 3
Figure 4
 
Figure 7
 
Figure 8
 
Figure 9
Figure 10
 
Figure 11
Figure 12
Figure 5
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness.  Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.