FIELD CONTROLS UV-28HPC User Manual

Page of 12
 
Page 2
I. 
INDICATION FOR USE 
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for 
use in the mitigation, treatment, or prevention of any disease or condition. 
II. GENERAL 
INFORMATION 
There are different size units available, depending on the square footage of your home.  See chart below for 
determining your homes needs. 
Model 
Minimum 
Duct 
Width 
Volts 
Amps 
Hz 
Watts 
Max Air 
Temp °F 
Lamp Intensity at 1 
meter 
Recommended 
Max Sq. Feet 
UV-12C 9 
120 
0.5 
60 
30 
190° 
37 
μW/cm
2
 
1500 
UV-18C 14 
120 
0.5 
60 
30 
190° 73 
μW/cm
2
 
2000 
UV-28C 22 
120 
1.1 
60 
60 
150° 
105 
μW/cm
2
 
3000 
UV-28 22 
120 
1.1 
60 
60 
150° 
105 
μW/cm
2
 
3000 
UV-12HP 9 240 
0.5 
60 
30 
190° 37 
μW/cm
2
 
1500 
UV-18HP 14 240 
0.5 
60 
30 
190° 73 
μW/cm
2
 
2000 
UV-28HP 22 240 
1.1 
60 
60 
150° 105 
μW/cm
2
 
3000 
UV-12HPC 9  240 
0.5 
60 
60 
190° 37 
μW/cm
2
 
1500 
UV-18HPC 14  240 
0.5 
60 
30 
190°  73 
μW/cm
2
 
2000 
UV-28HPC 22  240 
1.1 
60 
30 
150° 105 
μW/cm
2
 
3000 
The UV-12C,18C,28C,12HPC,18HPC, and 28HPC units are equipped with a circuit board to monitor the operation 
of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the cover of the 
unit.  The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light.  
After 8,320 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous 
“YELLOW” color on the LED light and the internal alarm will beep every 15 minutes.  After 9,000 hours of lamp 
operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED 
light and the internal alarm will beep every 5 minutes.  The board also checks if the UV lamp is burned out.  If the 
lamp is burned out, the circuit board will indicate this by a continuous “RED” color on the LED and the internal 
alarm will beep every 5 minutes. 
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power 
OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to 
direct UVC light from any source. 
WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier. 
WARNING: Designed for a closed duct system. Do not mount near a supply or a return air opening. 
WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).  For 
use on gas fired, oil fired, electric and split system heat pump forced air systems*.  This product is NOT designed 
to be mounted outside on gas fired or heat pump packaged units**. 
*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. 
**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building
 
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness.  Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.