8.  Wipe off the bulb glass with the supplied alcohol wipe.  Then insert the bulb 
through the center hole of the mounting base.  (See Figure 5)  The power cord 
must be 90° to the view port hole on the mounting base. 
9.  With the ballast pressed against the mounting base, rotate the ballast clockwise 
90°. 
10. Plug the power supply cord into a standard electric wall outlet.  Check bulb 
operation by looking through the view port hole.  NOTE:    The view port hole is 
made of glass and will not allow any UVC rays to pass through
.  A blue glow 
should be seen in the duct. 
11. If blue glow is not seen, make sure base is 
properly installed onto duct.  There is a proving 
switch located on the base that needs to be 
seated properly onto the duct.  Make sure that 
when base is mounted that the plated 
washer on the switch is raised 
approximately 3/16” and the switch is fully 
engaged.
  (See Figure 6) 
12. With standard duct tape or like material, seal all 
joints and seams of the plenum near the 
mounting location to reduce any direct viewing 
of light. 
MAINTENANCE 
WARNING:  Unplug unit from outlet before 
commencing inspection and cleaning. 
NOTE:    Wear disposable, non-absorbent 
protective gloves prior to inspection 
procedure in case of accidental breakage of 
glass. 
1.  We recommend inspecting and cleaning bulb at least every 6 months depending upon your home environment and 
condition of conventional filters and duration of use and their replacement cycle. 
2.  To maintain the bulbs maximum output intensity , replace your Air+Health™ Air Purifying System bulb annually, 
depending upon your home environment using the replacement procedure below.  The bulb should operate 
continuously for maximum bulb life and light effectiveness. 
REPLACEMENT PROCEDURE 
WARNING:  Unplug unit from wall outlet before starting replacement procedure. 
NOTE:  Wear disposable, non-absorbent protective gloves prior to replacement procedure 
in case of accidental breakage of glass.
 
1.  Rotate the Air+Health™ ballast assembly counter-clockwise until it stops.  (See Figure 7) 
2.  Remove the ballast assembly and bulb from the mounting base.  (See Figure 5) 
3.  Remove the bulb from the bulb socket.  (See Figure 4) 
4.  Install replacement bulb into bulb socket.  Do not handle the bulb with bare hands.  Oils on the 
hands tend to reduce bulb intensity. 
5.  Wipe off the glass with the supplied alcohol wipe. 
6.  Position the ballast assembly power cord 90° to the view port hole on the mounting base.  (See 
Figure 7) 
7.  Slide the bulb thought the hole in the mounting base.  (See Figure 5) 
8.  Press the ballast against the mounting base and rotate the ballast assembly clockwise until it 
stops.  (See Figure 8) 
9.  After assembly is firmly in place, plug the power supply cord into a standard electrical wall outlet.  
Check bulb operation by looking through the view port hole.  A blue glow should be seen in the 
duct. 
Figure 7
Figure 8
Figure 5
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent
eye damage or blindness. Never operate the Air+Health™ Air Purifying System out of the plenum. Avoid touching the
glass portion of the bulb with your hands. 
Figure 6