Chamberlain 3245M 1/3 HP User Manual

Page of 36
23
ADJUSTMENT STEP 1
Adjust the UP and DOWN Travel Limits
Limit adjustment settings regulate the points at which the 
door will stop when moving up or down.
To operate the opener, press the Door Control push bar. 
Run the opener through a complete travel cycle.
•  Does the door open and close completely?
•  Does the door stay closed and not reverse 
unintentionally when fully closed?
If your door passes both of these tests, no limit 
adjustments are necessary unless the reversing test fails 
(Adjustment Step 3, page 25).
Adjustment procedures are outlined below. Read the 
procedures carefully before proceeding to Adjustment 
Step 2. Use a screwdriver to make limit adjustments. 
Run 
the opener through a complete travel cycle after each 
adjustment. 
NOTE: 
Repeated operation of the opener during 
adjustment procedures may cause the motor to overheat 
and shut off. Simply wait 15 minutes and try again. If 
anything interferes with the door’s upward travel, it will 
stop. If anything interferes with the door’s downward travel 
(including binding or unbalanced doors), it will reverse.
HOW AND WHEN TO ADJUST THE LIMITS
•  If the door does not open completely but opens at 
least five feet (1.5 m):
   Increase up travel. Turn the UP limit adjustment screw 
clockwise. One turn equals 2" (5 cm) of travel.
   
NOTE: To prevent the trolley from hitting the cover 
protection bolt, keep a minimum distance of 2-4" 
(5 cm - 10 cm) between the trolley and the bolt.
•  If door does not open at least 5 feet (1.5 m): 
   Adjust the UP (open) force as explained in Adjustment 
Step 2.
•  If the door does not close completely:
   Increase down travel. Turn the DOWN limit adjustment 
screw counterclockwise. One turn equals 2" (5 cm) of 
travel.
   If door still won't close completely and the trolley 
bumps into the pulley bracket (page 4), try lengthening 
the door arm (page 21) and decreasing the down limit.
•  If the opener reverses in fully closed position:
   Decrease down travel. Turn the DOWN limit adjustment 
screw clockwise. One turn equals 2" (5 cm) of travel.
Without a properly installed safety reversal system, persons 
(particularly small children) could be SERIOUSLY INJURED or 
KILLED by a closing garage door.
•  Incorrect adjustment of garage door travel limits will 
interfere with proper operation of safety reversal system. 
•  If one control (force or travel limits) is adjusted, the other 
control may also need adjustment.
•  After ANY adjustments are made, the safety reversal system 
MUST be tested. Door MUST reverse on contact with 1-1/2" 
high (3.8 cm) object (or 2x4 laid flat) on floor.
•  If the door reverses when closing and there is no 
visible interference to travel cycle:
   If the opener lights are flashing, the Safety Reversing 
Sensors are either not installed, misaligned, or 
obstructed. See Troubleshooting, page 18.
   Test the door for binding: Pull the emergency release 
handle. Manually open and close the door. If the door is 
binding or unbalanced, call for a trained door systems 
technician. If the door is balanced and not binding, 
adjust the DOWN (close) force. See Adjustment Step 2.
To prevent damage to vehicles, be sure fully open door 
provides adequate clearance.
Left Side Panel
Limit Adjustment Screws
Cover Protection 
Bolt
2-4"
(5-10 cm)
Adjustment Label