White Rodgers 94-388 THRU 94-396 WR/RBM TYPE 121 Leaflet

Page of 1
www.white-rodgers.com
08
RELAYS and
TRANSFORMERS
94-388 THRU 94-396 WR/RBM TYPE 121
Straight-Through Wiring, Replaces 
/
2
 Pole Devices Used Primarily in 
Residential Central Air Conditioning
FEATURES
• Replaces many Type 7 contactors used by OEM’s.
• Universal style mounting bracket fits existing mounting holes.
• Screw terminals and 
/
4
 quick connect terminals for easy installation.
SPECIFICATIONS
Temperature Range . . . . . . . . . . . . . . . . .   –40°F to 50°F
Mechanical Life (no load) . . . . . . . . . . . . .   Conforms to UL and ARI specifications
Electrical Life  . . . . . . . . . . . . . . . . . . . . . .   Conforms to ARI specifications
   
  94-388 thru 94-390 achieve 200,000
   
  cycles, make LRA at .5 pf, break 25% of
   
  FLA at .75 pf at rated voltage, 0,000
   
  cycles make and break LRA at .5 pf rated
   
  voltage
   
  94-394 thru 94-396 achieve 00,000
   
  cycles, make LRA at .5 pf, break 25% of
   
  FLA at .75 pf at rated voltage, 6,000
   
  cycles make and break LRA at .5 pf rated
   
  voltage
Weight (approximate) . . . . . . . . . . . . . . . .   7 oz.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. file number E75492
   
  C.S.A. file number LR49538
Coils Frequency . . . . . . . . . . . . . . . . . . . .   50/60 Hz
Coil Insulation. . . . . . . . . . . . . . . . . . . . . .   Class B (30°C)
Termination. . . . . . . . . . . . . . . . . . . . . . . .   Screw and Double 
/
4
 Q.C.
Operate. . . . . . . . . . . . . . . . . . . . . . . . . . .   85% of nominal coil voltage; 
   
  0% maximum safe operate
Duty Cycle  . . . . . . . . . . . . . . . . . . . . . . . .   Continuous
 
 
Model Number 
Voltage 
 
Res DC 
Current 
Nominal 
Max. Inrush
 
* 30 Amp 
** 40 Amp 
AC 
OHMS 
MA 
VA 
VA
 
94-388
 
94-394
 
24 
6.5 
208 
20
 
94-389
 
94-395
 
20 
420 
42 
20
 
94-390
 
94-396
 
208/240 
825 
20
Approximate Overall Dimensions
3
/
4
 x 2” x 2
/
2
COIL DATA
 
Type 
Voltage 
FLA 
LRA 
RES
 
94-388 
277 
30 
50 
40
 
thru 
480 
30 
75 
40
 
94-390 
600 
30 
50 
40
 
94-394 
277 
40 
200 
50
 
thru 
480 
40 
00 
50
 
94-396 
600 
40 
80 
50
CONTACT RATINGS
1 POLE DEFINITE
PURPOSE CONTACTORS 
WITH BUS BAR (30A THRU 40A)
2.445
2.541
2.313
1.625
2.000
.875
1.625
.215
TYP. 4
40 Amp Model
(with cover)
* 30 amp models have no cover on top as in line drawing below
** 40 amp models have cover on top as in picture above
30 Amp Model (No Cover)