Emerson Process Management 3422 User Manual

Page of 398
 Reference, Installation, and Operations Manual
Section 5: Startup and meter configuration
3-9000-743 Rev S
June 2013
Meter Corrections page
 147
5.6.11
Meter Corrections page 
Figure 5-14  Field Setup Wizard - Meter Corrections page 
1.
From the 
Field Setup Wizard - Meter Corrections Page
, choose the desired settings:
a.
Flow profile correction - Only enabled for Daniel JuniorSonic® Ultrasonic Gas 
Flow Meters and if Flow profile correction (for JuniorSonic® only) was selected 
on the Startup Page.
b.
Flow profile correction factor is to be used - If Live or Fixed was selected for both 
temperature and pressure on the Startup Page, then you can choose from 
Calculated or Fixed for a correction factor. Selecting Fixed requires you to enter a 
value from 0.9 to 1.0 for Fixed correction factor. If Not used was selected for 
either temperature or pressure on the Startup Page, then you can choose from 
Fixed or Default for a correction factor. Calculated will be disabled. Selecting 
Fixed requires you to enter a value from 0.9 to 1.0 for Fixed correction factor. The 
default value is 0.95. 
For Daniel Mark II Ultrasonic Gas Flow Meters only, the Fixed option is only 
available for DFI boards running version 3.72 or later firmware. 
Daniel CUI version 4.21 is the final version that supports Daniel Mark II Gas Ultrasonic 
meters. If you are communicating with a Daniel Ultrasonic Mark II Gas Flow Meter, you do 
not need to uninstall version 4.21 or earlier versions of Daniel CUI before installing 
MeterLink. Version 4.21 and earlier versions of Daniel CUI should not be run 
simultaneously with MeterLink.