Chateau™
20011956
NOTE: If you need to test the inlet pressure and/or 
manifold pressure, there are two (2) test ports available 
along the right side front edge between the firebox side 
and outer casing. The upper test port is inlet pressure. 
The lower test port is manifold pressure. (Refer to 
Figure 8)
CAUTION: Turn off the gas supply before 
removing test port plug.
23.  Using a 7/16” nut driver, remove the threaded plug 
from the test port.
24.  Thread the supplied extension adaptor into the 
open test port.
25.  Attach a 1/4” diameter pressure gauge flexible hose 
fully onto the barb of the adaptor.
26.  Turn on gas supply and operate valve with remote 
control as needed to indicate gas pressure.
CAUTION: Turn off the fireplace and gas 
supply before removing test port adaptor 
and replacing plug.
27.  After test, remove extension adaptor and replace 
plug securely.
28.  Turn on gas supply and check that plugs are tight 
and leak free.
Special Feature for Cold Climates
This gas control system has the option of a continu-
ous pilot feature. This allows the user to change from 
a spark to pilot system to a standing pilot system for 
direct vent appliances during cold climate conditions to 
keep the firebox warm.
When the continuous pilot mode is activated and the 
fireplace is turned ON, the pilot will spark and light. 
When the fireplace is turned OFF, the pilot will stay ON 
when the main burner shuts OFF.
The continuous pilot mode can be activated or de-acti-
vated by the hand held remote control transmitter.
16.  If you chose to install the optional back-up battery 
pack (No. DVTBBK), you must install a wall box 
within 15 feet (4.6 m) of the fireplace. Assemble the 
connectors on one end of the supplied extension 
wire harness to the mating connectors on wire har-
ness within the control box. Make sure to connect 
black coded wire to black and red coded wire to 
red.
17.  The other end of the extension wire harness should 
be connected to the wiring of the back-up battery 
holder located within a wall box.
18.  Insert the supplied four (4) “AA” batteries into the 
battery older. Be sure to note correct polarity for 
each battery.
19.  Mount electrical wall box containing back-up bat-
teries at a convenient location with 15 feet (4.6 m) 
of the fireplace. Cover wall box using a blank wall 
plate.
20.  The fireplace remote system is ready for use.
21.  Reassemble access panel, burner assembly, gas 
supply connector, brick panels, logs, embers, 
andirons and lava rock in reverse order of removal. 
(Refer to Log, Lava Rock and Ember Placement 
section. 
22.  Turn on gas supply and check that all connections 
are tight and leak free.
������
������������
����
ADJ.
S
Remote/Off
IPI
PO
WER
AUX
Learn
I
Continous
Pilot
Off/On
Junction Box
Main Module
FP1792
Fig. 10  Connect 120V AC electrical supply.
Main Module
Learn 
Button
Power Module