Planar PS5550 User Manual

Page of 21
 
 
________________________________________________________________ 
V1.0 
4 / 21
 
Document 020-1156-00 Rev B
 
Count  
Byte 
Byte  
Bytes 
order 
2~3 
 
Example1: Set Brightness as 76 for TV-02 and this command is valid 
Send (Hex Format)  
Name   Lengt
ID 
Command 
Type 
Comman
Value
1  
Value
2  
Value
3  
CR  
Hex  
0x38 
0x30 
0x32 
0x73 
0x24 
0x30 
0x37 
0x36 
0x0
Reply (Hex Format) 
Name   Lengt
ID 
Command 
Type 
CR  
Hex  
0x34 
0x30 
0x32 
0x2B 
0x0
 
Example2: Set Brightness as 176 for TV-02 and this command is NOT valid 
Send (Hex Format)  
Name   Lengt
ID 
Command 
Type 
Comman
Value
1  
Value
2  
Value
3  
CR  
Hex  
0x38 
0x30 
0x32 
0x73 
0x24 
0x31 
0x37 
0x36 
0x0
Reply (Hex Format) 
Name   Lengt
ID 
Command 
Type 
CR  
Hex  
0x34 
0x30 
0x32 
0x2D 
0x0
Example3: Set Tint as 32 for TV-03 and this command is valid 
Send (Hex Format)  
Name   Lengt
ID 
Command 
Type 
Comman
Value
1  
Value
2  
Value
3  
CR  
Hex  
0x38 
0x30 
0x33 
0x73 
0x27 
0x30 
0x33 
0x32 
0x0
Reply (Hex Format) 
Name   Lengt
ID 
Command 
Type 
CR  
Hex  
0x34 
0x30 
0x33 
0x2B 
0x0
 
Example4: Set Tint as 75 for TV-03 and this command is NOT valid 
Send (Hex Format)  
Name   Lengt
ID 
Command 
Type 
Comman
Value
1  
Value
2  
Value
3  
CR  
Hex  
0x38 
0x30 
0x33 
0x73 
0x27 
0x30 
0x37 
0x35 
0x0