Vermont Casting NVC39 User Manual

Page of 28
11
NVC Series B-Vent
20000194
6. Place the top logs onto the locator notches. 
Ensure 
that the logs a
re secure. (Fig. 12)
7. Place ember material. See "Ember Material Place-
ment" section.
   
NVC36    NVC39  
NVC43
  Front Left Log 
BB6 
BC5 
BD6
  Front Right Log 
BB7    
BC6 
BD7
  Rear Log 
BE5 
BC7 
BD8
  Top Left Log 
BB9 
BC8 
BD9
  Top Right Log 
BB10 
BC9 
BD10
Lava Rock
The lava rock provided with this fireplace must be 
placed on the firebox base on either side of the burner 
assembly. Do not place lava rock in combustion pan.
Under no circumstances should this lava 
rock be placed on any part of the burner 
assembly.
Ember Material Placement
Separate the ember material into small pieces, roughly 
1/2" in diameter, and place onto the burner in front of 
the front logs. Do NOT pack down, leave in fluffy, loose 
condition for more realistic ember effect.
Flame Adjustment
For fireplaces equipped with HI/LO valves, flame ad-
justment is accomplished by rotating the HI/LO adjust-
ment knob located near the center fo the gas control. 
(Fig. 13 or 14)
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99   djt
Fig. 13  Flame adjustment knob for Honeywell valve.
HV102
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
HV116
SIT 820 knob
1/14/02   djt
IH
LO
Fig. 14  Flame adjustment knob for SIT valve.
HV116
Fig. 12   Log locations.
FP
NVC36 LOG SET
8-11-98
BE5 Log Rear
BB9 Log Top Left
BB10 Log Top Right
BB6
Log Front 
Left
BB7
Log 
Front 
Rigth
NVC36
FP
NVC43 LOG SET
8-12-98
BD8 Log Rear
BD9 Log Top Left
BD10 Log Top Right
BD6
Log Front 
Left
BD7
Log 
Front 
Right
NVC43
NVC39 LOG SET
8-12-98
BC7
Log 
Rear
BC8 Log Top Left
BC9
Log Top Right
BC5 Log 
Front 
Left
BC6
Log Front 
Right
NVC39
Flame Characteristics
It is important to periodically perform a visual check 
of the pilot and burner flames. Compare them to the , 
pictorials illustrated below. (Figs. 15 or 16) If the flame 
patterns appear abnormal contact a qualified service 
provider for service and adjustment.
FP584
NVB
12/4/97
H
I
LO
E
A
PIL
OT
Nova Sit 822
Valve
3/8"-1/2"
FP392
NVC-PILOTS
11/21/96
ELECTRONIC
IGNITION
Fig. 15  Proper pilot flame height.
FP392/585
Electronic
Ignition