Vermont Casting NVC39 User Manual

Page of 28
22
NVC Series B-Vent 
20000194
Remote Controls
Optional remote control units are available to control 
different functions of the appliance.
 
Model 
Function(s) Controlled
 
MRC1 
ON/OFF
 
MRC2 
ON/OFF and Temperature
 
MRC3 
ON/OFF and Temperature control  
 
 
with a digital and a programmable  
 
 
24 hour clock
 
IMT 
Wall mounted thermostat control
Ceramic Refractory Panels
Ceramic refractory panels are available to line the fire-
box area. 
 
Unit 
Kit Model
 
NVC36 
NV36CR
 
NVC39 
NV39CR
 
NVC43 
NV43CR
Take care when handling the refractory panels as they 
are fragile until held in place and supported.
Installation, refer to Figures 24 & 25
1.  Remove the window frame assembly.
2.  Remove the logs.
3.  Place the lower supports for the side refractory pan-
els on the base of the firebox. Place each support so 
that the slotted hole fits over the forward screw head 
along the edge of the base.
4.  Lay the angular base panels in place on the floor of 
the firebox on either side of the burner housing as-
sembly.
5.  Loosely attach the top adjustable tabs to the studs 
located in the top of the firebox toward the front cor-
ners.
6.  Place the rear refractory panel in place. Locate the 
'small brick' edge of the panel into the two small 
supports on the back panel just above the rear log 
support.
7.  Slide the side refractory panels into place to hold 
the rear panel secure. Adjust the top adjustable tabs 
to hold the side panel against the firebox wall and 
secure the tab. Repeat the procedure on the other 
side.
8.  Replace the logs and window frame assembly.
For aesthetic purposes we recommend lining up the 
horizontal mortar lines.
Adjustable 
Tab
Side 
Panel
Floor 
Refractory 
Panel
Lower Side Supports
FP1193
Fig. 24  Install ceramic refractory panels.
Adjustable 
Tab
Side 
Panel
Floor 
Refractory 
Panel
Rear Refrac-
tory Panel
Rear Panel 
Support 
Brackets
Firebox 
Back
Rear Log Support
FP1194
Fig. 25  Place the rear panel on rear support brackets.
Arched Door Front
The arched door front kit is designed to visually en-
hance the appearance of the NVC fireplace. 
To install the door front simply position the magnets as 
shown in Figure 26. Place the arched door into position 
and peel off the plastic. (Fig. 27)
FP1195
Arched door front
2/27/02   djt
FP1195
Fig. 26  Install magnets.
Magnets