Monessen Hearth DBX24C User Manual

Page of 36
33D4047
9
DFX & DBX Series Vent Free Fireplaces
FIREPLACE INSTALLATION
FIREPLACE LOCATION
Carefully select the best location for installation of your unvented fireplace. The following factors 
should be taken into consideration.
  Clearance to side wall, ceiling, woodwork and window or other combustibles. Refer to “Clear-
ances” section on Page 10. Minimum clearances to combustibles must be maintained.
•  
Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return 
air registers for forced air furnaces / air conditioners, windows or doors.
•  
Installation must provide adequate ventilation and combustion air.
•  
DO NOT INSTALL THIS MODEL IN A BEDROOM OR BATHROOM.
•  
Location should be out of high traffic areas and away from furniture and draperies due to 
heat from firebox.
•  
Never obstruct the front opening of the unvented fireplace or restrict the flow of combustion 
and ventilation air.
•  
Minimize modifications to existing construction. Refer to Figure 4 below for location sugges-
tions.
•  
Do not install in the vicinity where gasoline or other flammable liquids may be stored. The 
unvented firebox must be kept clear and free from the combustible materials.
FP2440
fireplace locations
Figure 4 - 
Possible Fireplace Locations
FP440