Monessen Hearth CDV7 User Manual

Page of 68
CDVSC7 & CDV7 Series Gas Fireplace
8
69D3011
FIReplaCe InSTallaTIon 
A listed manual shutoff valve must be installed upstream of 
the  appliance.  Union  tee  and  plugged  1/8"  NPT  pressure 
tapping point should be installed upstream of the appliance. 
Figure 41
IMpoRTanT: Install main gas valve (equipment shutoff valve) 
in an accessible location. The main gas valve is for turning on 
or shutting off the gas to the fireplace. 
Check  your  building  codes  for  any  special  requirements  for  locating  equipment  shutoff  valve  to 
fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. 
Excess sealant in pipe could result in clogged burner system valve.
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 41. Locate 
sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel 
supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. 
A sediment trap collects moisture and contaminants and keeps them from going into the burner 
system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system 
may not run properly. 
noTe: The gas line connection may be made using 1/" rigid tubing or an approved flex connector. 
Since some municipalities have additional local codes it is always best to consult your local authorities 
and the current edition of the National Fuel Gas Code ANSI.Z3.1, NFPA54. In Canada CSA-B149 
(1 or ) Installation Code. 
w
a
R
n
In
G
only  persons  licensed  to  work  with  gas 
piping  may  make  the  necessary  gas 
connections to this appliance.
C
au
TI
on
a  manual  shutoff  valve  must  be  installed 
upstream  of  the  appliance.  union  tee 
and  plugged  1/8”  npT  pressure  tapping 
point should be installed upstream of the 
appliance. 
Figure 41
C
au
TI
on
use  pipe  joint  sealant  that  is  resistant  to 
liquid petroleum (lp) gas.
3" Minimum
FP1978
gas connection
Pipe Nipple
Cap
Figure 41 - 
Gas Connection 
Tee Joint
Approved Flexible 
Gas Line 
CSA Design-Certified Equipment Shutoff Valve 
with 1/8" NPT Tap*
Sediment Trap/Drip Leg 
natural Gas
From Gas Meter 
(4.5" w.c. to 10.5" w.c. Pressure)
propane/lp
From External Regulator 
(11" w.c. to 13" w.c. Pressure)