CDVSC7 & CDV7 Series Gas Fireplace
69D3011
5
pRoDuCT FeaTuReS 
pRoDuCT SpeCIFICaTIonS
  This  appliance  has  been  certified  for  use  with  either 
natural or propane gas. See appropriate data plates.
  This appliance is not for use with solid fuels.
  The appliance is approved for bedroom or bedsitting 
room installations.
  The appliance must be installed in accordance with local 
codes if any. If none exist use the current installation 
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in 
Canada.
  This appliance is mobile home approved.
  The appliance must be properly connected to a venting 
system.
  The appliance is not approved for closet installations.
  This appliance is approved to be vented with Simpson-
Duravent and MHSC Twist-Lock Direct Vent Compo-
nents. 
FP2284a
CDV7 controls
Off/Pilot/On Knob 
Remote Control  
Switch Receiver
Figure 1 - 
CDV7 Series Fireplace 
Hi/Lo Knob 
Blower 
Control 
On/Off/RS 
Switch 
Ignitor
FP84
The classification “noncombustible material” includes, but 
is not limited to stone, brick and mortar. Noncombustibles 
are safe to overlay the black-painted metal face (includ-
ing radiant plates) and do not pose a fire hazard. Do not 
allow any noncombustible finish material to extend past or 
interfere with fireplace opening.
The classification “combustible material” includes, but is not 
limited to plywood, drywall and particle board. Combustible 
materials may contact the sides, bottom or back of firebox. 
Do  not  overlay  the  black  painted  face  with  combustible 