Flames from the pilot, front and rear burner should be 
visually  checked  as  soon  as  the  heater  is  installed.
 
In addition, periodically check the flames visually during 
operation.
CHECK THE PILOT FLAME
The  pilot  flame  must  always  be  present  when  the 
heater is in operation. 
It should just touch the top of the 
thermocouple tip for natural. Refer to Figure 21 for correct 
pilot flame. 
If the pilot flame does not touch the thermocouple, then 
the main burner cannot function reliably. Refer to Figure 
22 
for incorrect shape of pilot flame.
Figure 21 - 
Correct Appearance of Pilot Flame
FP2114
millivolt correct flame
FP2114
Thermocouple
for Natural  
Thermocouple
for LP
Figure 22 - 
Incorrect Appearance of Pilot Flame
FP2115
Millivolt wrong flame
FP2115
Thermocouple
for LP
Thermocouple
for Natural 
FLAME APPEARANCE
Figure 23 - 
Burner Flame Appearance - CFX24 
CORRECT LOG FLAME APPEARANCE
In normal operation at full rate after 15 minutes, the follow-
ing flame appearances should be observed:
Burner will have a random pattern of yellow flames. Refer 
to Figures 23 and 24. 
There should be glowing embers in 
front of burner.
NOTE: The front flames and embers will be an opaque 
orange color during the burn off time. 
Figure 24 - 
Burner Flame Appearance - CFX32 
LG591