Monessen Hearth IDV380PVC User Manual

Page of 40
16 
57D0016
VENT INSTALLATION 
MANIFOLD REMOVAL AND INSTALLATION
The manifold is shipped attached to insert. It may be removed  to allow tight installation. Mani-
fold may be loosened and rotated for desired pipe location.  
1.  Remove brick liner and baffle. 
2.  Remove manifold. Place manifold 
in fireplace. 
3.  Route flex vent through chimney 
from above. See Figure 10. Leave 
an extra 3" (914mm) at the top. 
4.  Attach flex vent to manifold. See 
Figure 11. Seal with silicone and 
attach with screws. 
5.  Place  manifold  in  an  upright 
position.  Have  someone  pull 
on the excess flex vent. Figure 
12. Temporarily attach flex vent 
to top of chimney. Leave some 
extra slack in flex vent. 
6.  Slide insert into place. Guide 
the  manifold  over  the  insert 
until  it  is  fully  in  place. 
Figure 13.
7.  Remove any slack from flex 
vent. Attach manifold to insert. 
Figure 13.
8.  Remove any excess slack in 
flex line. Attach vent termina-
tion.  Figure 13.
Figure 12 - Pulling On 
Excess Flex  Vent 
Figure 13 - Sliding Insert 
Into Place 
Manifold 
Chimney 
Figure 10 - Placing 
Manifold Into Fireplace 
Figure 11 - Attaching 
Flex Vent to Manifold 
Flex Vent 
Extra 3" 
(914mm) 
Manifold 
Flex Vent 
Chimney 
Manifold 
Chimney 
Excess 
Flex Vent 
Slack in 
Flex Vent 
Manifold
Bracket
Nut
Insert  
Excess Slack Taken 
Out of Flex Vent 
Vent 
Termination 
Chimney 
9.  Replace 
baffle and 
brick liner. 
Bracket
Nut