Monessen Hearth IDV380PVC User Manual

Page of 40
28 
57D0016
PILO
T
OF
F
P
IL
O
T
ON
OPERATING INSTRUCTIONS
  LIGHTING PILOT FOR THE FIRST TIME  
LEAK TESTING (continued) 
You may check for gas leaks with the following methods only:
  •  Soap and water solution
  •  An approved leak testing spray
  •  Electronic sniffer
Check for gas leaks in each of the following locations:
  •  Pipe from the gas supply line connection to the gas valve
  •  Burner thread inlet 
•  Field made joints
  •  Pilot  
•  Factory made joints
  •  Each joint or connection 
•  All joints on valve and control body
If  using  a  soap  and  water 
solution  to  test  for  leaks, 
DO NOT spray solution onto 
control body. 
W
ARNING
NOTE:  Remove any excessive pipe compound from the connections. Excessive pipe compound can 
set off electronic sniffers. 
The control has an interlock device that does not allow the lighting of the insert up 
to the moment the safety device of the flame has not  interrupted the gas flow. After 
that period of time (when the magnet is closed), it is possible to start the lighting 
operation. 
The gas control knob is designed to be operated by hand. DO NOT use any tools 
during this operation. Damaged knobs may result in serious injury. 
W
ARNING
1.  Depress and turn knob counterclockwise 
 
to pilot position. 
2.  Push pilot knob in and hold in while pressing piezo ignitor 
several times until pilot ignites. Continued to hold pilot 
knob in for several seconds after ignition. Release and 
check that pilot continues to burn. 
If the pilot does not stay lit, repeat steps 1 and 2. 
  LIGHTING PILOT  
Figure 32  - Pilot Position 
If  the  knob  does  not  “pop”  out  to 
its  original  position  when  released, 
turn off gas to appliance and contact 
qualified service technician. 
W
ARNING