Monessen Hearth IDV490PVC User Manual

Page of 40
14
57D0016
IDV380/IDV490 Fireplace Insert
VeNtiNG iNStAllAtiON 
MANiFOlD ReMOVAl AND iNStAllAtiON
The  manifold  is  shipped  attached  to  insert.  It  may  be 
removed to allow tight installation. Manifold may be loos-
ened  and  rotated  for  desired 
pipe location.
1.  Remove  brick  liner  and 
baffle.
.  Remove  manifold.  Place 
manifold in fireplace.
3.  Route flex vent through chim-
ney from above. Figure 10. 
Leave an extra 3" (914 mm) 
at the top.
FP2629
flex vent
Flex 
Vent
Chimney
Manifold
Bracket 
Nut
FP69
Figure 10 - 
Place Manifold into Fireplace
FP2630
attach flex vent
Extra 3"
Chimney
Flex 
Vent
Manifold
FP630
Figure 11 - 
Attach Flex Vent to Manifold
4.  Attach  flex  vent  to 
manifold. Figure 11. 
Seal  with  silicone 
and  attach  with 
screws.
FP2631
pull excess vent
Excess 
Flex 
Vent
Chimney
Slack in 
Flex Vent
Manifold
FP63
Figure 12 - 
Pull on Excess Flex Vent
5. 
Place  mani-
fold  in  an  upright 
position.  Pull  on 
excess vent. Figure 
12.
  Temporarily 
attach  flex  vent 
to  top  of  chimney. 
Leave  some  extra 
slack in flex vent.
FP2632
place insert
Vent 
Termination
Chimney
Excess Slack 
Take out of Flex 
Vent
Manifold
Bracket
Nut
FP63
Figure 13 - 
Slide Insert into Place
Insert
6.  Slide insert into place. 
Guide  the  manifold 
over  the  insert  until  it 
is fully in place. Figure 
13
7.  Remove any slack from 
flex vent. Attach mani-
fold  to  insert.  Figure 
13
8.  Remove  any  excess 
slack in flex line. Attach 
v e n t   t e r m i n a t i o n . 
Figure 13
9.  Replace  baffle  and 
brick liner.