Monessen Hearth IDV490PVC User Manual

Page of 40
18
57D0016
IDV380/IDV490 Fireplace Insert
eleCtRiCAl iNStAllAtiON
ReMOte WAll MOuNteD SWitCh
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. At-
tach the wall switch in a junction box at the desired location on the wall. Figure 18.  
NOte: extended lengths of wire may cause the fireplace not to function properly. longer 
length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always 
check with local code.
eleCtRiCAl WiRiNG
This insert will work without any electrical supply. Electricity is only needed to operate blower.
Verify proper operation after servicing. 
W
ARN
iNG
electrical connections should only be performed by a qualified, licensed electrician. Main power 
must be off when connecting to main electrical power supply or performing service. All wiring 
shall be in compliance with all local, city and state codes. the appliance, when installed, must 
be electrically grounded in accordance with local codes, or in the absence of local codes, with 
the National Electrical Code ANSI/NFPA 70 (latest edition)
 and Canadian Electrical Code, CSA 
C22.1
.
label all wires before disconnecting when servic-
ing controls. Wiring errors can cause improper and 
dangerous operation.
CA
uti
ON
PILOT
HI
LO
ON
OFF
FP1933
wall switch wiring
Figure 17 -
Wiring Diagram for Wall Switch
Sparker
Thermocouple
Piezo Igniter
Thermopile
Pilot Assembly
Switch
Millivolt 
Valve
TH
TP
TH/TP
ON
OFF
Optional 15' 
Wall Switch
Optional 
Remote Control
ON
OFF
ON
OFF