MAiNteNANCe
yeARly SeRViCe PROCeDuRe
Failure to inspect and maintain heater may lead to improper combustion and a potentially dangerous 
situation. A qualified technician should do the following once a year. 
1.  Check pilot flame. Flame should touch approximately 3/8" of the top of thermopile and touch top 
of thermocouple. Figure 43. If not, contact dealer for service. 
.  Turn gas control knob to “OFF” position to shut off gas to heater. See step “To Turn Off Gas”, Page 
26.  Allow heater to cool for 15 minutes. Remove faceplate (see instructions included with face 
plate) and glass. Page 28. 
3.  Carefully remove log set. If logs are severely deteriorated, replace logs. Check logs for sooting. A 
small amount of soot along bottom of logs is normal. If excessive sooting is found, heater must be 
adjusted. Contact dealer where you bought heater. 
4.  Clean burner and burner ports. Figure 44
5.  Replace log set and rock wool per instructions on Pages 19-1. Replace glass. Make sure gasket 
along perimeter of glass contacts face of firebox and forms an airtight seal. Realign if airtight seal 
is not formed. Replace glass and glass frame if damaged.
6.  Inspect area behind face plate. Clean if necessary. Check gas control valve and all gas lines. If 
damaged, do not use heater. Contact your dealer.
7.  Start pilot and turn on main burner. Flames should be orange/yellow and not touch top of firebox. 
If pilot or main burners do not burn correctly, contact your dealer for service. Monitor blower opera-
tion.
FP1943
pilot flame
Thermocouple
Thermopile
FP1943
Figure 43 -
Before taking unit apart, check pilot 
flame. Flame should touch thermo-
couple and thermopile.
FP640
FP2640
burner ports
Check Burner Ports
Figure 44 -
Check Burner Ports and Burners