57D0016
IDV380/IDV490 Fireplace Insert
5
FP2621
IDV controls 
PRODuCt FeAtuReS  
  This appliance has been certified for use with 
either natural or propane gas. Refer to the 
appropriate data plates.
  This  appliance  is  not  for  use  with  solid 
fuels.
  The appliance is approved for bedroom or 
bedsitting room installations.
  The  appliance  must  be  installed  in  accor-
dance with local codes if any. If none exist 
use  the  current  installation  code.  ANSI 
Z3.1/NFPA 54 in the USA, CSA B149 in 
Canada.
  The appliance must be properly connected 
to a venting system.
PRODuCt SPeCiFiCAtiONS
Piezo Igniter
Figure 1 - 
IDV Series Fireplace Insert
Optional 
Remote 
Receiver
Blower Knob
ON/OFF Switch
OFF/Pilot/ON 
Knob
HI/LO Knob
Gas Shut-Off 
Valve
On/Off 
Remote 
Switch
FP61
W
ARN
iNG
this  appliance  may  be  installed  in  an 
aftermarket*,  permanently  located, 
manufactured home, where not prohibited 
by local codes
*Aftermarket: Completion of sale, not for purpose of resale, 
from the manufacturer.
hiGh eleVAtiONS
Input ratings are shown in BTU per hour and are certified 
without deration for elevations up to 4,500 feet (1,370 
m) above sea level.
For  elevations  above  4,500  feet  (1,370  m)  in  USA, 
installations  must  be  in  accordance  with  the  current 
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties  having  jurisdiction  for  installations  at  elevations 
above 4,500 feet (1,370 m).
GAS PReSSuReS
   
Natural 
Propane (LP)
  Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
10.5” w.c. 
13.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
    
 
Max.input  Min. input 
Orifice 
  Model 
Fuel 
Btu/h 
Btu/h 
Size
  IDV380NVC 
Nat. 
30,500 
0,500 
#35
  IDV380PVC 
LP 
8,000 
,000 
#53
  IDV490NVC 
Nat. 
40,000 
6,500 
#30
  IDV490PVC 
LP 
37,500 
9,000 
#50
GAS SPeCiFiCAtiONS & ORiFiCe SiZe
The IDV Series gas inserts are equipped with a variable 
speed output gas control.
NOte: IDV Series gas inserts operate without any elec-