Monessen Hearth IDV490PVC User Manual

Page of 40
57D0016
IDV380/IDV490 Fireplace Insert
9
FP2624
insert placement
iNStAllAtiON
iNSeRt PlACeMeNt
  The insert must be placed within a code-conforming masonry fireplace or a tested and 
listed zero-clearance (UL-17, solid fuel) fireplace. Repair any fireplace damage prior to 
installation.
  Because the insert uses a circulation blower, clean the fireplace, smoke shelf and chim-
ney before installing.
  This heater may be placed in  a bedroom. Please be aware of the large amount of heat 
this appliance produces when determining a location.
Figure 5 - 
Insert Placement
For tight fits you may remove the 
manifold. Refer to "Remove the 
Manifold" Section
For minimum dimensions, 
Refer to Page 7
The insert protrudes into 
the fireplace. Refer to 
Page 7 for dimensions.
The gas line should be 
installed prior to insert 
placement
Run the power cord 
either side of the 
insert along the face
Use the leveling bolts for 
fireplaces with recessed 
floors
Run the on/off 
switch wires to the 
right - behind the 
surround panels
FP64
For minimum 
dimensions, 
Refer to Page 