47
HDV Series Direct Vent Gas Fireplace
CleANING and MAINteNANCe 
W
ARNING
turn  off  gas  before  servicing  fireplace.  It 
is  recommended  that  a  qualified  service 
technician perform these check-ups at the 
beginning of each heating season
BuRNeR, PIlot AND CoNtRol CoMPARt-
MeNt
Keep  the  control  compartment,  logs,  and  burner  areas 
surrounding the logs clean by vacuuming or brushing at 
least twice a year.  Make sure the burner porting, pilot air 
opening and burner air opening are free of obstructions 
at all times.
PIlot FlAMe
The flames from the pilot should be visually checked as 
soon  as  the  heater  is  installed  and  periodically  during 
normal operation. the pilot flame must always be pres-
ent when the fireplace is in operation. 
Figure 68. The 
pilot  flame  has  three  distinct  flames,  one  engulfing  the 
thermopile, one engulfing the thermocouple, and the other 
reaching to the main burner.                   
BuRNeR
Inspect area around the injector. Remove any lint or foreign 
material with a brush or vacuum. 
BuRNeR FlAMe
The  flames  from  the  burner  should  be  visually  checked 
as soon as the heater is installed and periodically during 
normal operation. In normal operation, at full rate, and after 
operating for about 15 to 30 minutes, the flame should be 
yellow and slightly taller than the rear log. Figure 69
If the flame is blue and only in the center, turn off unit and 
let cool. After unit is cool, remove logs and check to make 
sure rock wool is placed correctly. Replace logs. 
Note: The type of installation, vent system configuration, 
and wind effects may cause the flame patterns to vary.
FP2487
HDV pilot flame
Thermocouple
Thermopile
FP487
Figure 68 - 
Pilot Flame
Millivolt Pilot
FP2453
hooded pilot flames
Sensor
Thermopile
FP453
Signature 
Command 
System Pilot
LG695
HDV log flames
Figure 69 - 
Burner Flame Appearance