Monessen Hearth HBDV400 User Manual

Page of 54
10 
54D5031
0"–12"
Maximum
Depth
12" Minimum
71"Minimum
Minimum 4"
From Both
Side Walls
FIREPLACE
WALL
COMBUSTIBL
MATERIAL
AREA
4"
3"
2.5"
45°
2.5"
2.5"
1"
1.5"
1.5"
STUD
Follow these instructions carefully to ensure safe installation. Failure to follow 
in struc tions exactly can create a fi re hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other 
than wood fl ooring. If installed on carpet or vinyl fl ooring, the appliance shall be installed 
on a metal, wood or noncombustible material panel ex tend ing full width and depth of 
the appliance.
W
ARNING
CLEARANCES
CLEARANCES TO COMBUSTIBLES 
MANTEL CLEARANCES 
NOTE: The combustible area above the facing must not protrude more than 
3
/
4
" from the facing. If it does, 
it is considered a mantel and must meet the mantel requirements listed in this manual. 
Figure 5 - Clearances 
Figure 5a - Mantel clearances.
NOTE
All mantel shelves, regardless of depth, should be a mini-
mum of 12" from top opening of fireplace. Mantel shelf 
shall not exceed 12" maximum depth at 12" minimum 
height from opening.