VENT INSTALLATION
Figure 7 - Combustible Clearances for Vent Pipe
W
ARNING
WARNING
This fireplace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.
WARNING
Horizontal sections of this vent system require a minimum of 3" clearances to
combustibles at the top of the flue and 1" clearance at the sides and bottom until
the flue penetrates the outside wall. A minimum 1" clearance all around the flue is
acceptable at this point of penetration.
Vertical sections of this vent system require a minimum of 1" clearance to combustibles
on all sides of the pipe.
combustibles at the top of the flue and 1" clearance at the sides and bottom until
the flue penetrates the outside wall. A minimum 1" clearance all around the flue is
acceptable at this point of penetration.
Vertical sections of this vent system require a minimum of 1" clearance to combustibles
on all sides of the pipe.
A Minimum of 3" Clearance
to the Top Is Required Along
Horizontal Length until Flue
Pipe Penetrates Outside Wall.
A Minimum 1" Clearance to
Combustibles Permitted All
Around Flue at Outside Wall