Monessen Hearth HBDV400N/PSC7 User Manual

Page of 64
HBDV7 Series Direct Vent Gas Fireplace
54D8000
15
VeNt INStAllAtIoN
W
ARNING
this  fireplace  must  be  vented  to  the 
outside. the venting system must NeVeR 
be  attached  to  a  chimney  serving  a 
separate  solid  fuel  burning  appliance. 
each gas appliance must use a separate 
vent  system.  Do  not  use  common  vent 
systems.
W
ARNING
Horizontal  sections  of  this  vent  system 
require  a  minimum  of  3”  clearances  to 
combustibles at the top of the flue and 1” 
clearance  at  the  sides  and  bottom  until 
the  flue  penetrates  the  outside  wall.  A 
minimum 1” clearance all around the flue 
is acceptable at this point of penetration. If 
vertical rise is 7
Z\x” feet or higher when top 
venting, the clearance to combustibles is 
1” on all sides of the horizontal run.
Vertical  sections  of  this  vent  system 
require  a  minimum  of  1”  clearance  to 
combustibles on all sides of the pipe.
FP2586
vent pipe clearance
*3"
**1"
**1"
*3”
**1”
**1”
3356 ” 
(841 mm)***
***296 " (753 mm) 
for 300 Series
48”
(1219 mm)***
***4456O” (1130 mm)
for 300 Series
* A Minimum 3” Clearance to the Top is 
Required Along Horizontal Length until 
Flue Pipe Penetrates Outside Wall
** A Minimum 1” Clearance to Combus-
tibles Permitted All Around Flue at Out-
side Wall
FP095a
Figure 16 - 
Combustible Clearances for Vent Pipe