Monessen Hearth HBDV400N/PSC7 User Manual

Page of 64
HBDV7 Series Direct Vent Gas Fireplace
54D8000
9
Figure 6 - 
Secure Fireplace to Floor and Framing Studs
SeCuRe FIRePlACe to FlooR or FRAMING
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use 
two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) 
screws to attach fireplace to framing. The side nailing flanges are 1/" or 5/8" to accommodate 
different wall thickness.
FP2583
secure fireplace
Insulation 
Board
Screws
Nailing Flange
Screws
Framing
Nailing 
Flange
Screws
FP583
FINISHING MAteRIAl
Note: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to 
final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating 
of Zero) may be used to cover the black surface of the appliance. A 300°F minimum adhesive may 
be used to attach facing materials to the black surface. If joints between the finished wall and the 
fireplace  surround  are  sealed,  a  300°F  minimum  sealant  material  (General  Electric  RTV103  or 
equivalent) must be used.
Screws
W
ARNING
Do Not ReMoVe 
INSulAtIoN 
BoARD