Monessen Hearth MCFS36 User Manual

Page of 4
Sold  by:
DFS/MCFS36-MHS3704
Rev. 07-04
Warning:
• It is recommended that the screen be used during operation of this log 
set. Always ensure the screen has adequate spaces to allow for passage 
of combustion air to the gas  log set.
• Correct installation of the ceramic fiber logs, proper location of the 
heater and periodic cleaning are necessary to avoid potential service 
problems with sooting.
• Keep small chidren and animals away from the open flame of the gas log
set at all times.
• There may be a start-up odor associated with the heating of the logs. 
The odor should diminish in 2-3 hours of operation with the burner at its
highest setting with the fan in the off position.
REGULATORY APPROVAL
The DFS and MCFS series has been tested and approved by CSA as an
unvented room heater to the latest ANS Z21.11 requirements. Approved for
installation in an aftermarket manufactured (mobile) home, where not pro-
hibited by state or local codes. This unit complies with requirements to be
classified as a zero clearance unit.
SPECIFICATIONS
32" Corner 32" Corner 36" Corner 36" Corner
Surround
Hearth
Surround Hearth
Width of mantel
62-3/8"
62-3/8"
63-3/8"
63-3/8"
Height w/o hearth 48-1/4"
5"
48-1/4"
5"
Distance from 
corner to front 
center of mantel
35-1/2"
37-1/2"
Distance from 
corner to front 
edge along wall
44-1/8"
47"
Opening width
38"
Hardwood Surround Dimensions
32" Wall 32" Wall 36" Wall 36" Wall *36" Wall  *36" Wall
Surround Hearth
Surround Hearth
Surround Hearth
Width of mantel
50-1/2"
58"
54-3/8"
61-1/4"
58"
64-1/2"
Height w/o hearth
48"
5"
48-1/4"
5"
53"
5"
Depth
17-1/4"
21-3/8"
21-3/4"
25-1/2"
22"
25-1/2"
Opening width
38"
42"
42"
Opening height
35-7/8"
35-3/4"
40-3/4"
Width of mantel top 58"
62"
64-1/2"
Depth of mantel top 21-1/8"
25-1/2"
25-1/2"
149 Cleveland Drive • Paris, Kentucky 40361
www.monessenhearth.com
MADE IN U.S.A.
To avoid personal injury or property damage, the product described by this brochure must
be installed, operated and maintained in strict compliance with the instructions packaged
with the product and all applicable building or fire codes. Contact local building or fire
officials about restrictions and installation inspection requirements. All photographs and
drawings on this brochure are for illustrative purposes only and are not intended for, nor
should they be used as a substitute for the instructions packaged with the unit.
Appearance and specifications of the product are subject to change without notice.
© 2004 Monessen Hearth Systems, Inc.
 
B
A
Stud Location
MCFS36 DFS32/24 DFS36
DFS42
A 41-1/4"
37-1/4"
41-1/4" 47-1/4" 
B 43-1/2"
37-3/4"
37-3/4" 37-3/4" 
C 30-1/2"
28-3/4"
32-1/2"  38-3/4" 
D 15-1/4"
14-3/8"
16-5/8" 19-3/8" 
E 71-1/2"
60-3/4"
65-1/4" 70-3/4" 
F 35-3/4"
30-3/8"
32-5/8" 35-3/8" 
G 21"
16"
16" 16"
H 50-1/2"
43"
46-1/4" 50"
 
A
C
H
D
G
F
E
Corner Installation
C
 
A
G
Inside Chase Installation
Product Specifications
Width
Height
Depth
Actual
Cert.
Framing Actual Framing Actual Framing
Model
MCFS36
DFS32
DFS36
Both
CSA
Both
CSA
Both
CSA
41" 
37" 
41" 
41-1/4" 
37-1/4" 
41-1/4" 
43" 
37-1/2" 
37-1/2" 
43-1/2"
37-3/4"
37-3/4"
20-1/2" 
16" 
16"
21" 
16" 
16" 
26" 
20-1/2" 
20-1/2" 
DFS42
Both
CSA
47" 47-1/4" 37-1/2" 37-3/4" 16" 
16" 
20-1/2" 
 
A
Recessed Installation
G
C
Manual 
Control 
BTU 
(x1000)
*MCFS36
Thermostat
Control 
BTU 
(x1000)
NG
LP
LP
NG
18-28 18-28
20-28
20-38 20-38
Millivolt 
Control 
BTU 
(x1000)
NG
LP
20-38 20-38
20-36 20-36
18-28 20-28
25-38 30-38
25-38 30-38
25-38 30-38
25-38 30-38
Hi/Lo
Control 
BTU 
(x1000)
LP
NG
18-28 21-28
20-38 22-38
20-38 22-38
18-28
Radiant or
Circulating
Opening
Height
DFS3224
Both
CSA
37" 37-1/4" 37-1/2" 37-3/4"
16" 
16" 
20-1/2" 
20-38 20-38
30-38
25-38 30-38
20-38 22-38
25-38
Vent Free Fireplace System 
Framing Dimensions