ELBOW INSTALLATION
The following are important points that should be observed when 
installing elbows on the fireplace.
1.  Securely nail down all four (4) support straps to the surround-
ing structure of all elbows not installed directly on top of the 
fireplace. 
IMPORTANT:  Use a minimum of two (2) 8-penny nails per 
strap. This allows the support strap to carry the weight of the 
chimney above the elbow and prevents this weight from break-
ing the elbow or chimney sections apart. 
2.  Do not use elbows in any combination that inclines the chimney 
more than 30° from vertical. See Figure 16.
3.   The minimum height of the fireplace and chimney system when 
using 1 pair of elbows is 13' 
  
Air Inlet Pipe 
Flue Pipe 
30° Elbow
Figure 16 - Elbow Supports 
CHIMNEY INSTALLATION
Figure 17 - Typical Chimney Offset Installation 
Storm Collar 
612 Flashing
Roof
Support Straps 
4.  Inclined portions of chimney are often used as stor-
age. Enclose the inclined portions of chimney that 
pass through living spaces to avoid contact with and 
possible damage to chimney. Maintain minimum air 
space of 2" between chimney and enclosing. See 
Figure 17.
5.  The length of inclined portion of chimney between 
elbows must not exceed 6' if it is not supported. 
 
The length of inclined portion of chimney between 
elbows must not exceed 20' if it is supported every 
6' with metal support straps.
6.  When enclosing the elbows and inclined portions of 
the chimney, enclosing materials must be installed 
vertically to maintain the required 2"minimum air 
space clearance to the chimney at the extremities 
of the offset. It is best that enclosing material not 
follow inclined portions of chimney.
Maintain 2" 
Minimum Air Space 
Clearance to 
Combustibles 
SC Chimney 
Cap
“S” Series 
Chimney 
Components 
SVTR 
Firestop 
Thimble 
(0°-15° Pitch) 
SE30 
Elbows