VeNtING INFoRMAtIoN
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
G =
Combustible 
  6" (152 mm)
Noncombustible 
  2" (51 mm)
F =
Combustible 
  6" (152 mm)
 
Noncombustible 
  2" (51 mm)
G
Balcony - 
with no side wall
M = 
Combustible &
Noncombustible
  12" (305 mm)
M
Balcony - 
with perpendicular side wall
M = 24" (610 mm)
P = 20” (508 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
E
 = Min. 6” (152 mm) for 
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O
 = 8’ (2.4 m) Min.
O
P
584-15
 
No. 
  of Caps 
 
D
Min.
 
  C
Max.
 
3’ (914 mm)   x D
Actual
 
 
6’ (1.8 m) 
1 x D
Actual
 
9’ (.7 m) 
/3 x D
Actual
 
1’ (3.7 m) 
1/ x D
Actual
D
Min.
 = # of Termination caps x 3
C
Max.
 = ( / # termination caps) x D
Actual
*Note: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or 
non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. . All mechanical air intakes within 10’ (1 m) of a 
termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must 
be a minimum of 1’ (305 mm) below the termination cap.
GeNeRAl INFoRMAtIoN ASSeMBlING VeNt PIPeS
uSA Installations
The venting system must conform to local codes and/or 
the current National Fuel Code ANSI Z3.1/NFPA 54.
Only  venting  components  manufactured  by  MHSC  may 
be used in Direct Vent systems and UL 1777 Listed Type 
Flex Venting.
Canadian Installations
The venting system must be installed in accordance with 
the current CSA-B149.1 installation code.
Flex Vent Pipes
Before joining the flex vent pipe to the unit, apply a bead 
of  high  temperature  sealant*  (provided)  to  the  4”  pipe 
exiting the fireplace. Secure flex vent pipe in place with 
a hose clamp (provided).
*Be sure the flex pipe overlaps at least 1” (5 mm) onto 
the collars of the fireplace and termination. If the termi-
nation has an internal bead, be sure to overlap and se-
cure 1” (5 mm) past the bead.
* Be sure the vent is actually crushed before proceeding. 
Apply a tug to be sure the vent will not slip off the collars.
Repeat process with 7” flex vent pipe. The same proce-
dure must be performed on the vent side.
FP2585
flex vent
Apply High Temperature 
Sealant
Hose Clamp
FP585
Figure 13 - 
Apply high temperature sealant to 4” and 7” pipes.
Figure 12 - 
Termination Clearances