Monessen Hearth HBDV400N/PV7 User Manual

Page of 64
HBDV7 Series Direct Vent Gas Fireplace
54D8000
5
FIRePlACe INStAllAtIoN
W
ARNING
only  persons  licensed  to  work  with  gas 
piping  may  make  the  necessary  gas 
connections to this appliance.
CA
ut
Io
N
A  manual  shutoff  valve  must  be  installed 
upstream  of  the  appliance.  union  tee  and 
plugged  1/8”  NPt  pressure  tapping  point 
should be installed upstream of the appliance. 
Figure 43
NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. 
Since some municipalities have additional local codes it is always best to consult your local 
authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada 
CSA-B149 (1 or 2) Installation Code. 
A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" 
NPT pressure tapping point should be installed upstream of the appliance. Figure 43
IMPORTANT:  Install  main  gas  valve  (equipment  shutoff  valve)  in  an  accessible  location.  The  main 
gas valve is for turning on or shutting off the gas to the 
fireplace. 
Check your building codes for any special requirements 
for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. Excess seal-
ant in pipe could result in clogged burner system valves.
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 43. Locate 
sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply 
and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment 
trap collects moisture and contaminants and keeps them from going into the burner system gas controls. 
If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly. 
CA
ut
Io
N
use pipe joint sealant that is resistant to liquid 
petroleum (lP) gas.
3" Minimum
FP1978
gas connection
Pipe Nipple
Cap
Figure 43 - 
Gas Connection 
Tee Joint
Approved Flexible 
Gas Line 
CSA Design-Certified Equipment Shutoff Valve 
with 1/8" NPT Tap*
Sediment Trap/Drip Leg 
Natural Gas
From Gas Meter 
(4.5" w.c. to 10.5" w.c. Pressure)
Propane/lP
From External Regulator 
(11" w.c. to 13" w.c. Pressure)