Monessen Hearth HBDV300N/PSC7 User Manual

Page of 64
HBDV7 Series Direct Vent Gas Fireplace
54D8000
31
Figure 52 - 
Signature Command Valve
FP1909a
signature command valve
alternate view
8/08
Pressure Inlet
Pilot Adjust-
ment Screw
Pressure Outlet
SIGNAtuRe CoMMAND - CHeCK GAS PReSSuRe and eleCtRICAl INStAllAtIoN
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is different from the fireplace, StoP! Do not install the 
appliance. Contact your dealer immediately.
.  To  ease  installation,  a  4"  (610  mm)  flex  line  with 
manual shut-off valve has been provided with this ap-
pliance. Install and attach 1/" gas line onto shut-off 
valve. 
3.  After completing gas line connection, purge air from 
gas line and test all gas joints from the gas meter to 
the fireplace for leaks. Use a solution of 50/50 water 
and soap solution or a gas sniffer. 
4.  To check gas pressures at valve, turn captured screw 
counter clockwise  or 3 turns and then place tubing 
to pressure gauge over test point. Turn unit to high.  
Figure 52. After taking pressure reading, be sure and 
turn captured screw clockwise firmly to reseal. Do not 
over torque. Check test points for gas leaks.
W
ARNING
Do  not  use  open  flame  to  check  for  gas 
leaks.
eleCtRICAl WIRING
General
1.  This fireplace is equipped with the Signature Control 
valve which operates on 6 volts. The 6 volt DC adapter 
plugs into the fireplace junction box A/C power supply. 
Four  (4)  “AA”  batteries  are  used  for  back  up  during 
power outages.
.  The Signature Command System can also be operated 
without A/C power. The system can run on four (4) “AA” 
batteries for approximately six (6) months under normal 
use.
3.  A/C  power  must  be  used  to  power  the A/C  module, 
blowers, lights and AUX accessories if used with this 
fireplace.
optional Accessory Requirements
1.  This  fireplace  may  be  used  with  a  wall  switch,  wall 
mounted thermostat and/or Signature Command wire-
less controls.
.  The command center control may be mounted on the 
wall with the use of the SCSWEK 15ft. wall mount exten-
sion kit.
W
ARNING
electrical  connections  should  only 
be  performed  by  a  qualified,  licensed 
electrician.  Main  power  must  be  off  when 
connecting to main electrical power supply 
or  performing  service. All  wiring  shall  be 
in compliance with all local, city and state 
codes. the appliance, when installed, must 
be electrically grounded in accordance with 
local codes or in the absence of local codes, 
with the National electrical Code ANSI/NFPA 
70 (latest edition) and Canadian electrical 
Code, CSA C22.1.
CA
ut
Io
N
label all wires before disconnecting when 
servicing controls. Wiring errors can cause 
improper and dangerous operation.