Monessen Hearth HBDV300N/PSC7 User Manual

Page of 64
HBDV7 Series Direct Vent Gas Fireplace
46
54D8000
LG752
HBDV log flames
CleANING and MAINteNANCe
W
ARNING
turn  off  gas  before  servicing  fireplace.  It 
is  recommended  that  a  qualified  service 
technician  perform  these  check-ups  at  the 
beginning of each heating season.
BuRNeR, PIlot AND CoNtRol CoMPARt-
MeNt
Keep  the  control  compartment,  logs,  and  burner  areas 
surrounding the logs clean by vacuuming or brushing at 
least twice a year.  Make sure the burner porting, pilot air 
opening and burner air opening are free of obstructions 
at all times.
PIlot FlAMe
The flames from the pilot should be visually checked as 
soon  as  the  heater  is  installed  and  periodically  during 
normal operation. the pilot flame must always be pres-
ent when the fireplace is in operation. 
Figure 69. The 
pilot  flame  has  three  distinct  flames,  one  engulfing  the 
thermopile, one engulfing the thermocouple or sensor, and 
the other reaching to the main burner.
              
BuRNeR
Inspect area around the injector. Remove any lint or foreign 
material with a brush or vacuum. 
BuRNeR FlAMe
The  flames  from  the  burner  should  be  visually  checked 
as soon as the heater is installed and periodically during 
normal operation. In normal operation, at full rate, and after 
operating for about 15 to 30 minutes, the flame should be 
yellow and slightly taller than the rear log. Figure 70
If the flame is blue and only in the center, turn off unit and 
allow to cool. After unit is cool, remove logs and check to 
make sure the back holes in the burner are not covered 
with rock wool. If the back holes are clear, add more rock 
wool to the center of the burner. Replace logs. 
Note: The type of installation, vent system configuration, 
and wind effects may cause the flame patterns to vary.
Figure 70 -
Burner Flame Appearance
LG75
FP1943
pilot flame
Thermopile 
Thermocouple 
FP1943
Millivolt Control 
Pilot
Figure 69 - 
Pilot Flame 
FP2453
hooded pilot flames
Sensor
Thermopile
FP453
Signature 
Command 
System Pilot