HBDV7 Series Direct Vent Gas Fireplace
6
54D8000
Note ReGARDING VeNteD PRoDuCtS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 
detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State  of 
Massachusetts requires the damper to be permanently removed 
or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 
bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve. 
Note ReGARDING VeNt FRee PRoDuCtS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 
bedroom or bathroom regardless of size or type in the State of 
Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve.
CARBoN MoNoxIDe DeteCtoR RequIReMeNtS
() Revise  10.8.3  by  adding  the  following  additional 
requirements:
(a)  
For  all  side  wall  horizontally  vented  gas  fueled 
equipment installed in every dwelling, building or structure used 
in  whole  or  in  part  for  residential  purposes,  including  those 
owned or operated by the Commonwealth and where the side 
wall exhaust vent termination is less than seven (7) feet above 
finished  grade  in  the  area  of  the  venting,  including  but  not 
limited to decks and porches, the following requirements shall 
be satisfied:
1.  Installation  of  carbon  monoxide  detectors.  At  the  time 
of  installation  of  the  side  wall  horizontal  vented  gas  fueled 
equipment,  the  installing  plumber  or  gas  fitter  shall  observe 
that a hard wired carbon monoxide detector with an alarm and 
battery  back-up  is  installed  on  the  floor  level  where  the  gas 
equipment is to be installed. In addition, the installing plumber 
or gas fitter shall observe that a battery operated or hard wired 
carbon  monoxide  detector  with  an  alarm  is  installed  on  each 
additional level of the dwelling, building or structure served by 
the side wall horizontal vented gas fueled equipment. It shall be 
the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired 
carbon monoxide detectors
 
a.  In the event that the side wall horizontally vented gas 
fueled equipment is installed in a crawl space or an attic, the 
hard  wired  carbon  monoxide  detector  with  alarm  and  battery 
back-up may be installed on the next adjacent floor level.
 
b.  In the event that the requirements of this subdivision 
can  not  be  met  at  the  time  of  completion  of  installation,  the 
owner shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said thirty 
(30) day period, a battery operated carbon monoxide detector 
with an alarm shall be installed.
Massachusetts Residents only — Please read and follow these special requirements
.  Approved  Carbon  Monoxide  Detectors.  Each  carbon 
monoxide  detector  as  required  in  accordance  with  the  above 
provisions shall comply with NFPA 70 and be ANSI/UL 034 
listed and IAS certified.
3.  Signage.  A  metal  or  plastic  identification  plate  shall  be 
permanently  mounted  to  the  exterior  of  the  building  at  a 
minimum height of eight (8) feet above grade directly in line with 
the exhaust vent terminal for the horizontally vented gas fueled 
heating appliance or equipment. The sign shall read, in print size 
no less than one-half (1/) inch in size, “GAS VENT DIRECTLY 
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. Inspection. The state or local gas inspector of the side wall 
horizontally vented gas fueled equipment shall not approve the 
installation  unless,  upon  inspection,  the  inspector  observes 
carbon monoxide detectors and signage installed in accordance 
with the provisions of 48 CMR 5.08()(a)1 through 4.
(b) exemptions: The following equipment is exempt from 48 
CMR 5.08()(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not 
Required To Be Vented" in the most current edition of NFPA 54 
as adopted by the Board; and
.  Product Approved  side  wall  horizontally  vented  gas  fueled 
equipment  installed  in  a  room  or  structure  separate  from  the 
dwelling,  building  or  structure  used  in  whole  or  in  part  for 
residential purposes.
(c)  Manufacturer  requirements  —  Gas  equipment  Venting 
System  Provided.
  When  the  manufacturer  of  Product 
Approved side wall horizontally vented gas equipment provides 
a  venting  system  design  or  venting  system  components  with 
the  equipment,  the  instructions  provided  by  the  manufacturer 
for installation of the equipment and the venting system shall 
include:
1. Detailed instructions for the installation of the venting system 
design or the venting system components; and
. A complete parts list for the venting system design or venting 
system.
(d) Manufacturer requirements — Gas equipment Venting 
System  Not  Provided.  
When  the  manufacturer  of  a  Product 
Approved  side  wall  horizontally  vented  gas  fueled  equipment 
does  not  provide  the  parts  for  venting  the  flue  gases,  but 
identifies “special venting systems,” the following requirements 
shall be satisfied by the manufacturer:
1.  The  referenced  "special  venting  system"  instructions  shall 
be  included  with  the  appliance  or  equipment  installation 
instructions; and
. The “special venting systems” shall be Product Approved by 
the Board, and the instructions for that system shall include a 
parts list and detailed installation instructions.
(e)  
A  copy  of  all  installation  instructions  for  all  Product 
Approved side wall horizontally vented gas fueled equipment, 
all  venting  instructions,  all  parts  lists  for  venting  instructions, 
and/or all venting design