   If a 90° elbow is used in the horizontal vent run, the horizontal 
vent length is reduced by 36" (914 mm). Figure 25. This does 
not apply if the 90° elbows are used to increase or redirect a 
vertical rise. Figure 25
Example: According to the vent graph, Figure 22, the maximum 
horizontal vent length in a system with a 7.5' vertical rise is 20’ 
(6 m) and if a 90° elbow is required in the horizontal vent it must 
be reduced to 17' (5.2 m). Refer to Page 17 “How to Use Vent 
Graph.”
In Figures 26 and 27, Dimension A plus B must not be greater 
than 17' (5.2 m).
   The maximum number of 45° elbows permitted per side wall 
installation is two (2). These elbows can be installed in either 
the vertical or horizontal run. 
   For each 45° elbow installed in the horizontal run, the length 
of the horizontal run MUST be reduced by 18" (45 cm). This 
does not apply if the 45° elbows are installed on the vertical 
part of the vent system.
   The maximum number of elbow degrees in a system is 270°. 
Figure 27
vENTING INSTaLLaTIoN 
hoRIZoNTaL TERMINaTIoN CoNFIGuRaTIoN (Continued)
7’6”
A
B
90°
FP2305
run reduction
Figure 25 - 
Horizontal Run Reduction 
FP2305
A
10’
B
7’
7’6”
FP2306
max vent run elbows
Figure 26 - 
Maximum Vent Run with Elbows
Example: 
Elbow 1   =   90°
 
Elbow 2   =   45°
 
Elbow 3   =   45°
 
Elbow 4   =   90°
Total Angular Variation   =   270°
A + B = 17' Maximum
90° Elbow = 3'
FP2306
Figure 27 - 
Maximum Elbow Usage 
1 + 2 + 3 + 4 = 270°