Monessen Hearth HVFL18 User Manual

Page of 44
10 
59D1015
A
C
D
B
    Model 
D
 
HVFL18 
18" 
13
1
/
4
"
 
27" 
17"
 
HVFL24 
22
1
/
4
13
1
/
4
28
1
/
2
17"
 HVFL24 with 30" Logs   25
1
/
2
13
1
/
4
32
1
/
2
17"
FIREPLACE AND HEARTH DIMENSIONS
Use manufacturer's installation and clearance requirements as defined in their manual.
The HVFL Series unvented room heater is approved for installation into the following unvented fireplaces:
GCUF Series Fireboxes Magnum36/42 or Lo-Rider36
NOTE: HVFL24 log set will not fit into GCUF32 fireboxes. 
The HVFL Series unvented room heater may also be installed into a Ventless Firebox Enclosure for Gas Fired Decorative 
Type Unvented Room Heaters per IAS Requirement No. 2-97 ANSI Z21.91-2001 (typically referred to as a "Universal 
Firebox"), as long as firebox hearth dimensions meet the minimum hearth dimensions shown below.
Figure 2 - Hearth Minimum Dimension
This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-
built fireplace, vent free appliance, or in listed ventless firebox enclosure. It has been 
design certified for these installations. 
Exception:  
DO  NOT  install  this  appliance  in  a  factory-built  fireplace  that  includes 
instructions stating it has not been tested or should not be used with unvented gas 
logs. 