Monessen Hearth HVFL18 User Manual

Page of 44
20 
59D1015
Pipe Coupling
To Heater 
Valve
Gas Supply 
Inlet 
CONNECTING THE GAS
NOTICE:  A  qualified  gas  appliance  installer  must  connect  the  heater  to  the  gas  supply.  Consult 
all local codes.
IMPORTANT: 
Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe. 
Manual Shutoff
Valve
Pipe
Stainless
Flexible Tube
Figure 15 - Gas Connection
Always  use  an  external  regulator  for  all  propane/LPG  heaters  and  high  pressure  one  to  two-pound  systems 
only,  to  reduce  the  supply  tank  pressure  to  a  maximum  of  13" w.c. This  is  in  addition  to  the  internal  regulator  in 
the heater valve.
Locations that the Pressure 
Tapping Point May Be Installed 
Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used 
per  National  Fuel  Code,  section  2.6.3,  providing  gas  meets  hydrogen  sulfide  limits, 
and  where  permitted  by  local  codes.  Gas  piping  system  must  be  sized  to  provide 
minimum  inlet  pressure  (Listed  on  Data  Plate)  at  the  maximum  flow  rate  (BTU/Hr). 
Undue pressure loss will occur if the pipe is too small.
A  manual  shutoff  valve  must  be  installed  upstream  of  the  appliance.  Union  tee 
and  plugged 
1
/
8
"  NPT  pressure  tapping  point  should  be  installed  upstream  of  the 
appliance. See Figure 15.
CAUTION 
CHECK GAS TYPE: The gas supply must be the same as stated on the heater’s rating 
plate.  If  the  gas  supply  is  different,  DO  NOT  INSTALL  THE  HEATER.  Contact  your 
dealer for the correct model. 
CAUTION