Monessen Hearth HVFL18 User Manual

Page of 44
36 
59D1015
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot.
Appliance  produces  unwanted 
odors.
Appliance shuts off during use.
Gas  odor  even  when  control 
knob is in OFF position.
When ignitor button is pressed, 
there is spark at ODS pilot, but 
no ignition.
POSSIBLE CAUSE
1.  Ignitor electrode positioned wrong.
2.  Ignitor electrode is broken.
3.  Ignitor  electrode  not  connected  to  ignitor 
cable.
4.   Ignitor cable pinched or wet. Keep ignitor cable 
dry.
5.  Broken ignitor cable.
6.  Bad piezo ignitor.
1.  Appliance  burning  vapors  from  paint,  hair 
spray, glues, etc.
2.  Gas leak.
3.  Initial burn off. 
1.  Not enough fresh air is available for ODS/ 
pilot to operate.
2.  Low line pressure.
3.  ODS/pilot is partially clogged.
4.  Defective Thermopile.
5.  Restrictions in incoming air flow. 
1.  Gas leak.
2.  Control valve defective.
1.  Gas supply turned off or manual shutoff valve 
closed.
2.  Control knob not in PILOT position.
3.  Control knob not pressed in while in PILOT 
position.
4.  Air in gas lines when installed.
5.  ODS/pilot is clogged.
6.  Gas regulator setting is not correct.
REMEDY
1  Replace ignitor.
2.  Replace ignitor.
3.  Reconnect ignitor cable.
4.  Free  ignitor  cable  if  pinched  by  any 
metal or tubing.
5.  Replace ignitor cable.
6.  Replace piezo ignitor.
1.  Ventilate room. Stop using odor causing 
products while heater is running.
2.  Locate and correct all leaks.
3.  Ventilate  room  and  turn  unit  on  high 
until odor is gone. Odor should be gone 
after 2 to 3 hours of continuous use. 
1.  Open window and/or door for ventila-
tion.
2.  Contact local gas company.
3.  Clean ODS/pilot.
4.  Check wire connections. Check output 
should be 500 milli-volts across TH/TP 
and TP Terminals with ON/OFF switches 
off.
5.  Check for bottom riser on glass door, 
sunken fireplace, excessive lava rock/
cinders densely packed against grate. 
1.  Locate and correct all leaks.
2.  Replace control valve.
1.  Turn  on  gas  supply  or  open  manual 
shutoff valve.
2.  Turn control knob to PILOT position.
3.  Press in control knob while in PILOT 
position.
4.  Continue holding down control knob. 
Repeat  igniting  operation  until  air  is 
removed.
5.  Replace ODS/pilot assembly or get it 
serviced.
6.  Check incoming pressure. Replace gas 
regulator.
Note: All troubleshooting items are listed in order of operation.
TROUBLESHOOTING
W
ARNING
Turn appliance OFF and allow to cool 
before  servicing.  Only  a  qualified 
service  person  should  service  and 
repair the heater.
W
ARNING