Monessen Hearth DEB30 User Manual

Page of 40
10 
44D0060
A
C
D
B
    Model 
D
 
DEB20 18" 
13
1
/   
4
"
 
27" 17"
 DEB24 
22
1
/   
4
" 13
1
/   
4
" 28
1
/   
2
" 17"
 DEB30 
25
1
/   
2
" 13
1
/   
4
" 32
1
/   
2
" 17"
FIREPLACE AND HEARTH DIMENSIONS
Use manufacturer's installation and clearance requirements as defi ned in their manual.
The DEB Series unvented room heater is approved for installation into the following unvented fireplaces:
GCUF Series Fireboxes 32, 36, or 42
The DEB Series unvented room heater may also be installed into a Ventless Firebox Enclosure for Gas Fired Decorative Type 
Unvented Room Heaters per IAS Requirement No. 2-97 ANSI Z21.91-2001 (typically referred to as a "Universal Firebox"), 
as long as firebox hearth dimensions meet the minimum hearth dimensions shown below.
Figure 2 - Hearth Minimum Dimension
This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-
built fi replace or in a listed ventless fi rebox enclosure. It has been design certifi ed for 
these installations. 
Exception:  DO NOT install this appliance in a factory-built fi replace that includes 
instructions stating it has not been tested or should not be used with unvented gas 
logs. 
W
ARNING