Monessen Hearth DEB30 User Manual

Page of 40
44D0060 
27
PLACING THE DECORATIVE ROCK 
DO NOT sprinkle volcanic rock on the logs, around the pilot, or on or near burners. This 
may cause sooting. Place volcanic rock only on the fl oor of the fi replace.
During initial operation of the new heater, burning logs will give off a paper burning 
smell and orange fl ames will be present. Simply open the windows for a few hours to 
vent the odor.
CAUTION
FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.
 
In addition, periodically check the flames visually during operation.
CHECKING THE PILOT FLAME
The pilot fl ame must always be present when the heater is in operation. 
It should just touch the top of the ther-
mocouple tip for natural. See Figures 27 and 29 for correct pilot flame. 
If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. See Figures 28 and 30 
for incorrect shape of pilot flame.
MILLI-VOLT CONTROL 
Figure 27 - Correct Appearance of Pilot Flame
Figure 28 - Incorrect Appearance of Pilot Flame
MANUAL CONTROL 
Figure 29 - Correct Appearance of Pilot Flame
Figure 30 - Incorrect Appearance of Pilot Flame
Thermocouple
for Natural  
Thermocouple
for LP
Thermocouple
for LP
Thermocouple
for Natural 
Thermocouple
for Natural 
Thermocouple
for Natural 
Thermocouple
for LP
Thermocouple
for LP