Monessen Hearth DEB30 User Manual

Page of 40
44D0060 
31
OPERATING INSTRUCTIONS
  1.  STOP! Read the safety information label.
  2.  Make sure the manual shutoff valve is fully open.
  3.  This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo 
ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions”, page 33.
  4.  Turn gas control knob clockwise 
 to the OFF position, set the thermostat to the lowest setting 
and turn ON/OFF switch to OFF position.
  5.  Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! 
Follow the instructions under “What To Do If You Smell Gas,” page 29.
  6.  From OFF position, turn the gas control knob counterclockwise 
 to IGN position. Push in 
control knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it may be 
necessary to press in the control knob for 30 seconds or longer to allow air to bleed out 
of the gas piping. 
  7.  With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
  8.  Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting 
off the gas while the probe is warming up. Release the control knob.
  9.  Turn gas control knob counterclockwise 
 to the ON position.
 10.  After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON 
position. NOTE: To use the thermostat function (if installed) the control knob must be set 
to “ON” and ON/OFF switch must be in the “OFF” position. 
 11.  If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and call your 
service technician or gas supplier.
Figure 36 - Pilot 
 MILLI-VOLT CONTROL 
LIGHTING INSTRUCTIONS 
 
TO TURN OFF GAS TO HEATER
 
  1.  Turn control knob clockwise 
 to OFF position to completely shut off the heater.
  2.  If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
  3.  If applicable: Turn off all electric power to the heater.
Figure 37 - Control Cover Plate for Milli-Volt 
Hi/Lo Control 
Ignitor Pilot Control
On/Off Switch
Piezo