Monessen Hearth DEB30 User Manual

Page of 40
34 
44D0060
OBSERVED PROBLEM
ODS/pilot lights, but flame 
goes out when control knob is 
released.
Burner does not light after ODS/
pilot is lit.
Burner backfires during com-
bustion.
Slight smoke or odor during 
initial operation.
Logs appear to smoke after ini-
tial operation.
Heater produces a whistling 
noise when burner is lit.
No gas to pilot. 
POSSIBLE CAUSE
1.  Control knob not fully pressed in.
2.  Control knob not pressed in long enough.
3.  Manual shutoff valve not fully open.
4.  Thermocouple connection loose at control 
valve.
5.  Pilot flame not touching thermocouple, which 
allows thermocouple to cool, causing pilot 
flame to go out. This problem could be caused 
by either low gas pressure, or a dirty or 
partially clogged ODS/pilot.
6. Thermocouple damaged.
7.  Control valve damaged.
1.  Burner orifice is clogged.
2.  Burner orifice diameter is too small.
3.  Inlet gas pressure is too low.
1.  Manifold pressure is too low.
2.  Burner orifice is clogged.
1.  Burner orifice is clogged or damaged.
2.  Burner is damaged.
3.  Gas regulator defective.
1.  Vapors from paint or curing process of logs.
1.  Turning control knob to HIGH position when 
burner is cold.
2.  Air in gas line.
3.  Dirty or partially clogged burner orifices.
1.  LP-regulator shut down due to inlet pressure 
too high.
REMEDY
1.  Press in control knob fully.
2.  After ODS/pilot lights, keep control 
knob pressed in for 30 seconds.
3.  Fully open manual shutoff valve.
4.  Hand tighten thermocouple connection 
until snug, then tighten 1/4 turn more.
5.  Contact local gas company.
6. Replace thermocouple.
7.  Replace control valve.
1.   Clean orifice.
2.  Replace burner orifice.
3.  Contact qualified service person.
1.  Contact local gas company.
2.  Clean burner or replace burner orifice.
1.   Clean burner or replace burner orifice.
2.  Replace burner.
3.  Replace gas regulator.
1.  Problem will stop after a few hours 
of operation. Run the heater with the 
damper open if you have one, or open a 
window for the first few hours.
2.  Log heater is intended to be smokeless. 
Turn OFF heater and call qualified 
service person.
1.  Turn control knob to LOW position and 
let warm up for a minute.
2.  Operate burner until air is removed from 
line. Have gas line checked by local 
gas company.
3.   Clean burner or replace burner orifice.
1.  Verify LP tank regulator is installed and 
set at 11" to 13" w.c.
2.  Replace regulator on heater.
TROUBLESHOOTING
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and 
the heater may backfi re when lit. If the gas quality or pressure is low, contact your local 
gas supplier immediately. 
W
ARNING